Heat & Glo  •  6000TR-OAK, 6000TR-OAK-IPI  •  383-901  Rev. K  •   5/06
17
HORIZONTAL VENTING
Kit No.
H Max. Run
DVP-TRAP
24" (610 mm)
Figure 11.  Corner Installation
NOTE: This model is tested and approved to
use 45° elbows in corner installations. Howev-
er, 90° elbows will result in better performance.
3. Match the amount of vertical you have in the sys-
tem with the chart to find the appropriate position
to set the Flue Restrictor (see Figure 9).
1    2    3    4   5
SETTINGS
1    2    3    4   5
Figure 10
4. Center the Flue Restrictor on vent  and secure in
place by using two self-tapping screws (see Fig-
ure 10).
5.  Reinstall the Exhaust Shield.
- CHART -
Vertical
Top Vent
NG
Top Vent
LP
Rear Vent
NG
Rear Vent
LP
4'
1-1
No
Restrictor
No
Restrictor
No
Restrictor
8'
2-2
1-2
1-1
No
Restrictor
15'
3-3
3-2
2-2
1-2
20'
3-4
3-3
3-3
2-3
25'
3-4
3-3
3-3
2-3
30'
4-4
3-4
3-4
3-3
35'
4-4
3-4
3-4
3-3
40'
5-4
4-4
4-4
3-4
Figure 9.
H
45-DEGREE
ELBOW
90-DEGREE
ELBOWS
Í