Листовка для Horstmann ChannelPlus H27XL

Скачать
Страница из 2
T
Th
he
e  s
siim
mp
plle
e  iin
ns
st
tr
ru
uc
ct
tiio
on
ns
s  b
be
ello
ow
w  a
ar
re
e  d
de
es
siig
gn
ne
ed
d  t
to
o  h
he
ellp
p  w
wiit
th
h  t
th
he
e  p
pr
ro
og
gr
ra
am
mm
miin
ng
g  o
of
f  t
th
he
e  u
un
niit
t..  A
Allll  t
th
he
e  f
fo
ollllo
ow
wiin
ng
g
iin
ns
st
tr
ru
uc
ct
tiio
on
ns
s   r
re
eq
qu
uiir
re
e   t
th
he
e   f
fr
ro
on
nt
t   f
flla
ap
p   t
to
o   b
be
e   llo
ow
we
er
re
ed
d..   P
Plle
ea
as
se
e   r
re
ep
plla
ac
ce
e   t
th
he
e   f
flla
ap
p   w
wh
he
en
n   n
no
or
rm
ma
all   o
op
pe
er
ra
at
tiio
on
n   iis
s
r
re
eq
qu
uiir
re
ed
d..
Electronic equipment can in some circumstances be affected by electrical interference. If the
programmer’s display becomes frozen or scrambled; or if you wish to revert back to the default time 
settings please use the following procedure.
F
FR
RO
ON
NT
T  C
CO
OV
VE
ER
R
S
SE
ET
TT
TIIN
NG
G  D
DA
AY
Y  A
AN
ND
D  T
TIIM
ME
E  O
OF
F  D
DA
AY
Y
Should you encounter any problems, please refer to the 
Q
Qu
ue
es
st
tiio
on
n  a
an
nd
d  A
An
ns
sw
we
er
r  section located on page 4.
The normal working position for the SET switch is in the PROG.RUN position. In order to remind the user
of this, the flap is unable to be closed with the switch in any other position.
R
RE
ES
SE
ET
TT
TIIN
NG
G  T
TH
HE
E  P
PR
RO
OG
GR
RA
AM
MM
ME
ER
R
Press SELECT once.
Programme goes from
AUTO to ALL DAY
Press SELECT again.
Programme goes from
ALL DAY to ON
Press SELECT again.
Programme goes from
ON to OFF
Press SELECT again.
Programme goes from
OFF to AUTO
Channel will operate
from first ON until last
OFF period 
Channel will be
continuously ON
Channel will be
continuously OFF
Programmer will return
to normal ON and OFF
times
B
BO
OO
OS
ST
T  F
FU
UN
NC
CT
TIIO
ON
N
-
-    
1
1  o
or
r  2
2  h
ho
ou
ur
r  t
te
em
mp
po
or
ra
ar
ry
y  o
ov
ve
er
rr
riid
de
e
Press BOOST button
once for 1 hour of
Hot Water or
Central Heating
Press BOOST button
twice for 2 hours of
Hot Water or
Central Heating
At any time during a BOOST
period press BOOST again to
return to normal programming
A
AD
DV
VA
AN
NC
CE
E  F
FU
UN
NC
CT
TIIO
ON
N
-
-  
B
Br
riin
ng
gs
s  f
fo
or
rw
wa
ar
rd
d  n
ne
ex
xt
t  o
on
n  o
or
r  o
of
ff
f  o
op
pe
er
ra
at
tiio
on
n
Press ADVANCE button once
to move to the next
ON/OFF time
To cancel the advance press the ADVANCE
button again. This will return the unit to
its normal programme
H
HO
OL
LIID
DA
AY
Y  F
FU
UN
NC
CT
TIIO
ON
N  
-
-  
A
Allllo
ow
ws
s  s
sy
ys
st
te
em
m  t
to
o  b
be
e  p
pr
ro
og
gr
ra
am
mm
me
ed
d  f
fo
or
r  u
up
p  t
to
o  3
32
2  d
da
ay
ys
s
Move SET switch to the
HOLIDAY position
Use the PLUS button to enter the
required number of nights
(MAX OF 32 NIGHTS)
Return SET switch to the
PROG.RUN position 
Whilst the HOLIDAY FUNCTION is in operation the system will remain OFF, the display will show the 
number of nights remaining. The HOLIDAY setting is an instant function and cannot be set in advance.
The HOLIDAY FUNCTION can be cancelled at any time by pressing any of the SELECT buttons. Normal 
programme functions will resume at the first ON period after the pre-set number of nights has expired.
IIN
NF
FO
OR
RM
MA
AT
TIIO
ON
N  A
AN
ND
D  A
AD
DV
VIIC
CE
E
Programming ON/OFF times
If a Heating or Hot water period is not required it can be cancelled by setting the ON and OFF
settings to the same time. Example ON 10:00am  OFF 10:00am
Your programmer will prevent you from accidentally overlapping ON and OFF times. 
Example: If the 2nd ON time is set at 12:00pm and then you try and set the 1st OFF at 12:30 pm the
OFF setting will ‘bounce’ by a 10 minute period until the 2nd ON time has been adjusted.
08
SETTING
ADVANCE
SELECT
Lower the front flap of the unit. On the Heating channel press the
ADVANCE and SELECT buttons together then release the buttons and
the programmer will return to the preset factory settings. 
P
Pa
ag
ge
e  2
2
BOOST
P
Pa
ag
ge
e  3
3
Move the SET
switch to the CLOCK
position.
Use PLUS and
MINUS buttons to
adjust time
Return SET switch to
PROG.RUN position
Use PLUS and
MINUS buttons to
adjust day
Press
ENTER
Move SET switch to
Central Heating 
or Hot Water 
position  
Repeat this
process for 2nd
and 3rd settings
Return SET
switch to PROG.RUN
position.
Press
ENTER
Press
ENTER
Press
ENTER
S
SE
ET
TT
TIIN
NG
G  T
TH
HE
E  O
ON
N  A
AN
ND
D  O
OF
FF
F  T
TIIM
ME
ES
S  
The SET slide switch must be in the PROG.RUN position for the following instructions.
The following actions work independently on either Hot Water or Central Heating.
S
SP
PE
EC
CIIA
AL
L  F
FE
EA
AT
TU
UR
RE
ES
S
SETTING
SET
TUE
MON
12:OO
PM
1:45
PM
SETTING 1ST
ON
OFF
6:30
AM
8:30
AM
SUN
Use PLUS
and MINUS 
buttons to
adjust day
Use PLUS and
MINUS 
buttons to adjust
the 1st ON  time.
Use the PLUS
and MINUS 
buttons to adjust
the 1st OFF time.
Programme the
remaining days.
If you require this
programme on any other
day of the week use the
PLUS and MINUS buttons to
select day and press COPY
ALL DAY
ON UNTIL
8:30
PM
ON
OFF
SUN
10:00
AM
SUN
SUN
SUN
AUTO
ON UNTIL
10:30
AM
AUTO
ON UNTIL
10:30
AM
AUTO
ON UNTIL
10:30
AM
AUTO
ON UNTIL
10:30
AM
AUTO
ON UNTIL
10:30
AM
BOOST 1 2
AUTO
ON UNTIL
11:30
AM
AUTO
ON UNTIL
11:30
AM
SUN
10:00
AM
10:00
AM
10:00
AM
10:00
AM
MON-FRI
SAT/SUN
1st ON  1st OFF   2nd ON    2nd OFF    3rd ON     3rd OFF
6:30 
A
AM
M
8:30 
A
AM
M
12:00 
P
PM
M
12:00 
P
PM
M
4:30 
P
PM
M
10:30 
P
PM
M
7:30 
A
AM
M
10:30 
A
AM
M
12:00 
P
PM
M
12:00 
P
PM
M
5:00 
P
PM
M
11:00 
P
PM
M
D
DE
EF
FA
AU
UL
LT
T  T
TIIM
ME
E  S
SE
ET
TT
TIIN
NG
GS
S
The default factory settings
are shown, however if you
wish to change these 
proceed as instructed below.
RESE
T
On the ChannelPlus display - Boost 1 is Hot water extension 1 or 2 hour and Boost 2 is Heating extension 1 or 2 hours