Справочник Пользователя для Exabyte EXB-8505 8mm

Скачать
Страница из 124
SCSI Commands
The SCSI-2 command set supported by the tape drive consists of 19
six-byte commands (Group 0 command set) and 6 ten-byte
commands (Group 1 command set). These commands are listed in
Table 5-2.
Note:
Tapes written and read in 8200 format use the SCSI-1
command set. See the EXB-8205 and EXB-8505 SCSI Reference
for more information.
Command
OP Code
Description
ERASE
19h
Causes the tape drive to erase all tape from the
current tape position to the physical end of tape.
INQUIRY
12h
Requests that information about the tape drive
parameters be sent to the initiator.
LOAD/UNLOAD
1Bh
Causes the tape drive to load or unload the data
cartridge.
LOCATE
2Bh
Allows you to position the tape at a specified logical
block address. Used in conjunction with the READ
POSITION command.
LOG SELECT
4Ch
Allows you to manage the counters that the tape drive
maintains about its write and read error recovery
operations.
LOG SENSE
4Dh
Allows you to retrieve statistical information about the
tape drive’s read and write error recovery operations.
MODE SELECT
15h
Allows you to specify medium, logical unit, and device
parameters.
MODE SENSE
1Ah
Enables the tape drive to report medium, logical unit,
or device parameters.
PREVENT/ALLOW MEDIUM
REMOVAL
1Eh
Allows or disallows the removal of the data cartridge
from the tape drive.
READ
08h
Transfers one or more bytes or blocks of data from the
tape to the initiator.
READ BLOCK LIMITS
05h
Requests that the tape drive return data identifying the
maximum and minimum logical block lengths
supported.
Table 5-2 SCSI-2 command set
5-4
EXB-8205 and EXB-8505
510504
(Standard and XL)
Interface Specifications