Galaxy 65 Troubleshooting
85
7.19.2 Disk Channel Errors
Disk channel errors are similar to disk-detected errors, except they are detected by the Galaxy 65 
Subsystem, instead of the disk drive. Some disk channel errors are displayed as text strings, others are 
displayed as hexadecimal codes. 
Table 7–8
 lists the error code descriptions. Most disk channel errors are informational because the 
Galaxy 65 Subsystem issues retries to correct any problem. Errors that cannot be corrected with retries 
will result in another critical event describing the affected array (if any). 
Table 7–7
?Common ASC and ASCQ descriptions
ASC
ASCQ
Descriptions
0C
02
Write error—auto-reallocation failed
0C
03
Write error—recommend reassignment
11
00
Unrecovered read error
11
01
Read retries exhausted
11
02
Error too long to correct
11
03
Multiple read errors
11
04
Unrecovered read error—auto-reallocation failed
11
0B
Unrecovered read error—recommend reassignment
11
0C
Unrecovered read error—recommend rewrite the data
47
00/01
FC CRC error
48
00
Initiator-detected error message received
Table 7–8
Disk channel error codes
Error Code
Description
Abort LkDn
I/O request was aborted because of third-party loop initialization procedure (LIP).
CRC Error
CRC error on data was received from a target.
Dev Busy
Target reported busy status.
Dn/Ov Run
Data overrun or underrun has been detected.
IOTimeout
Galaxy 65 Subsystem aborted an I/O request to this target because it timed out.
Link Down
Link down while communication in progress.
LIP
I/O request was aborted because of a channel reset. 
No Respon
No response from target.
Port Fail
Disk channel hardware failure. This may be the result of bad cabling.