Galaxy 65 User Guide
120
2
Select the array you want and press Enter.
The array menu displays.
3
Select Drive Status and press Enter 
The drive status screen displays showing the drives that are members of the array and that are assigned 
as dedicated spares.
Use the 
↑ 
or
 ↓ 
key to scroll through the drives. These are the drives that are currently members of the 
array.
4
Press Esc to return to the Array Menu.
C.2.2 Stopping the Array Initialization Process
If you find that you need to change the disks or some other array configuration, you can stop the array 
initialization process. 
Caution
If you stop the initialization process, the array goes offline and its data is not available to users.
You must delete the array before you can use the drives in another array.
To stop the array initialization process:
1
From the System Menu, select Array Menu and press Enter.
The Select Array screen displays with a list of existing arrays.
2
Select the array you want and press Enter.
The array menu displays.
3
Select Abort Initialization and press Enter 
The system confirms that you want to stop the initialization process.