Galaxy 65 User Guide
66
7.5.2 Auto Start Failure
Unless otherwise selected at installation time, all drives in the enclosure should automatically start their 
motors after power is applied. If this has not occurred there is a power problem (An alarm and power fault 
indication would normally be active).
Note
The SYSTEM LED will flash Green/Amber.
7.6 Dealing with Hardware Faults
Ensure that you have obtained a replacement module of the same type before removing any faulty 
module. 
Warning
If the Galaxy 65 Subsystem is powered up and you remove any module, replace it immediately. If 
the Subsystem is used with modules or module blanks missing for more than a few minutes, the 
Enclosure can overheat, causing power failure and data loss. Such use will invalidate the 
warranty.
• Replace a faulty drive with a drive of the same type and capacity. 
• All drive bays must be fitted with a Drive Carrier module or a dummy carrier module in order to 
maintain a balanced air flow.
• All the supplied plug-in power supply units, electronics modules and blank modules must be in place 
for the air to flow correctly around the cabinet. 
7.7 Continuous Operation During 
Replacement 
Depending on how the Subsystem is set up, if a disk unit fails, it can normally be replaced without 
interrupting the use of the system. 
In addition, each enclosure contains two Power Supply/Cooling modules, either of which can maintain 
power and cooling to the Subsystem while the other is replaced.
7.8 Problems Accessing the Galaxy 65 
Subsystem Using the Ethernet Port 
Problem: You cannot access the Galaxy 65 Subsystem using the default IP address of 10.0.0.1.
Your distributor or another user may have changed the default IP address. Use the RS-232 connection 
to access the Galaxy 65 Subsystem and configure the IP address.