Setup & Operation    1. Safety 
  
1.4  Emergency Stop 
If the Manipulator moves abnormally during operation, immediately press the Emergency 
Stop switch.  Stops the power supply to the motor, and the arm stops in the shortest 
distance with the dynamic brake and mechanical brake. 
However, avoid pressing the Emergency Stop switch unnecessarily while the Manipulator 
is running normally.    Otherwise, the Manipulator may hit the peripheral equipment since 
the operating trajectory while the robot system stops is different from that in normal 
operation. 
To place the system in emergency mode during normal operation, press the Emergency 
Stop switch when the Manipulator is not moving. 
Refer to the Controller manual for instructions on how to wire the Emergency Stop switch 
circuit. 
 
Free running distance in emergency 
The operating Manipulator cannot stop immediately after the Emergency Stop switch is 
pressed. 
The free running time/angle/distance of the Manipulator are shown below.  However, 
remember that the values vary depending on following conditions. 
Weight of the end effector    Weight of work piece    Operating pose   
Weight  Speed  Accel  etc. 
 Conditions for Measurement 
Accel Setting 
100 
Speed Setting 
100 
Load [kg] 
Weight Setting 
 
Joint #1 
Point where the 
emergency stop 
signal is input 
Start point of
operation 
Target point 
Stop point
Joint #2 
 
 
Controller RC180 
Manipulator 
G3-25*** G3-30*** G3-35*** 
Joint #1 + Joint #2  [sec.] 
0.8 
1.2 
0.6 
Free running 
time 
Joint #3 
[sec.] 
0.6 0.6 0.6 
Joint 
#1 
[deg.] 
41 53 57 
Joint 
#2 
[deg.] 
13 20 20 
Free running 
angle 
Joint #1 + Joint #2  [deg.] 
54 
73 
77 
Free running   
distance 
Joint 
#3 
G3-**1** 
[mm] 
95 95 95 
 
G3 Rev.1