Справочник Пользователя для Epson V7

Скачать
Страница из 344
5-128 
27. MOELLER PLC
27. MOELLER PLC
Available PLCs
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series is as follows:
Available Memory
The available memory setting range varies depending on the PLC model.  Be sure to set within the 
range available with the PLC to be used.  Use [TYPE] when assigning the indirect memory for macro 
programs.
 
Select PLC Type
PLC
Connection
PS4
PS4-201-MM1 (PRG port)
RS-232C [Wiring Diagram 1]
+
ZB4-303-KB1 Cable made by MOELLER
Item
Setting on PLC
V7 Comm. Parameter Setting
Baud rate
9600 bps
9600 bps
Port
1
1
Parity
Not provided
Not provided
Transmission code
Data length
8
8
Stop bit
1
1
Memory
TYPE
Remarks
M
(marker)
0
MW as word device