On a Windows operating system this is typically the directory C:\Program
Files\Fujitsu\ServerView Suite\plugins\viom\Manager.
Files\Fujitsu\ServerView Suite\plugins\viom\Manager.
Please modify the line StartOptions= by adding the option --debug trace
(two minus signs!):
(two minus signs!):
StartOptions=--debug trace
The trace file of the ServerView Virtual-IO Manager service is:
<ServerView Suite>\plugins\viom\Manager\logs\viom-manager.log
To also get full trace information from the module that configures connection
blades such as IBP 10/6, IBP 30/12, SB11A or SB11, add the debug option
trace,driverdbg to this line:
blades such as IBP 10/6, IBP 30/12, SB11A or SB11, add the debug option
trace,driverdbg to this line:
StartOptions=--debug trace,driverdbg
The ServerView Virtual-IO Manager service will then create a trace file for
each connection blade configuration command. These files are written to the
directory <ServerView Suite>\plugins\viom\Manager\logs.
each connection blade configuration command. These files are written to the
directory <ServerView Suite>\plugins\viom\Manager\logs.
The ServerView Virtual-IO Manager service creates a pre-defined maximum
number of log files. Each log file can have a pre-defined maximum size.
When the maximum number of log files is reached the oldest log file is auto-
matically deleted. New log information is written to a new log file.
number of log files. Each log file can have a pre-defined maximum size.
When the maximum number of log files is reached the oldest log file is auto-
matically deleted. New log information is written to a new log file.
The maximum number of log files can be changed by editing the file man-
log4j.properties in the directory:
log4j.properties in the directory:
<ServerView Suite>\plugins\viom\Manager.
In some cases it might be necessary to increase the number of log files in
order to keep trace information for a longer period of time. If so, please modify
the line log4j.appender.DebugAppender.MaxBackupIndex=25 and set
the property MaxBackupIndex to an appropriate value. Depending on the
amount of requests sent to the Virtual-IO Manager service, it might be nec-
essary to set this value to 50 or even higher if you want to keep log infor-
mation for about one week.
order to keep trace information for a longer period of time. If so, please modify
the line log4j.appender.DebugAppender.MaxBackupIndex=25 and set
the property MaxBackupIndex to an appropriate value. Depending on the
amount of requests sent to the Virtual-IO Manager service, it might be nec-
essary to set this value to 50 or even higher if you want to keep log infor-
mation for about one week.
The property MaxFileSize should not be increased, because it might make it
difficult to load files into an editor.
difficult to load files into an editor.
ServerView Virtual-IO Manager
357
15.3 Creating diagnostic data