T r o u b l e s h o o t i n g
POWER ON SELF TEST MESSAGES
The following is an alphabetic list of error-and-status 
messages that Phoenix BIOS and/or your operating 
system can generate and an explanation of each message. 
Error messages are marked with an *. If an error message 
is displayed that is not in this list, write it down and 
check your operating system documentation both on 
screen and in the manual. If you can find no reference 
to the message and its meaning is not clear, contact 
your support representative for assistance.
nnnn Cache SRAM Passed 
Where nnnn is the amount of system cache in kilobytes 
success-fully tested by the Power On Self Test. (This can 
only appear if you have an SRAM PC Card installed.)
*Diskette drive A error or Diskette drive B error 
Drive A: or B: is present but fails the BIOS Power On Self 
Test diskette tests. Check to see that the drive is defined 
with the proper diskette type in the Setup Utility, (See 
BIOS Setup Utility on page 33 for more information)
 an

that the diskette drive is installed correctly. If the disk 
drive is properly defined and installed, avoid using it and 
contact your support representative.
*Extended RAM Failed at offset: nnnn 
Extended memory not working or not configured prop-
erly. If you have an installed memory upgrade module, 
verify that the module is properly installed. If it is prop-
erly installed, you may want to check your Windows 
Setup to be sure it is not using unavailable memory 
until you can contact your support representative.
nnnn Extended RAM Passed 
Where nnnn is the amount of memory in kilobytes 
successfully tested.
*Failing Bits: nnnn The hex number nnnn
This is a map of the bits at the memory address (in 
System, Extended, or Shadow memory) which failed the 
memory test. Each 1 (one) in the map indicates a failed 
bit. This is a serious fault that may cause you to lose data 
if you continue. Contact your support representative.
*Fixed Disk x Failure or Fixed Disk Controller 
Failure (where x = 1-4) 
The fixed disk is not working or not configured properly. 
This may mean that the hard drive type identified in 
your setup utility does not agree with the type detected 
by the Power On Self Test. Run the setup utility to check 
for the hard drive type settings and correct them if 
necessary. If the settings are OK and the message appears 
when you restart the system, there may be a serious fault 
which might cause you to lose data if you continue. 
Contact your support representative.
*Incorrect Drive A type – run SETUP 
Type of floppy drive A: not correctly identified in Setup. 
This means that the floppy disk drive type identified in 
your setup utility does not agree with the type detected 
by the Power On Self Test. Run the setup utility to 
correct the inconsistency.
*Incorrect Drive B type – run SETUP
Type of floppy drive B: not correctly identified in Setup. 
This means that the floppy disk drive type identified in 
your setup utility does not agree with the type detected 
by the Power On Self Test. Run the setup utility to 
correct the inconsistency.
*Invalid NVRAM media type
Problem with NVRAM access. In the unlikely case that 
you see this message you may have some display prob-
lems. You can continue operating but should contact 
your support representative for more information.
*Keyboard controller error 
The keyboard controller test failed. You may have to 
replace your keyboard or keyboard controller but may 
be able to use an external keyboard until then. Contact 
your support representative.
*Keyboard error 
Keyboard not working. You may have to replace your 
keyboard or keyboard controller but may be able to
use an external keyboard until then. Contact your 
support representative.
*Keyboard error nn 
BIOS discovered a stuck key and displays the scan code 
for the stuck key. You may have to replace your keyboard 
but may be able to use an external keyboard until then. 
Contact your support representative.
*Monitor type does not match CMOS – Run SETUP
Monitor type not correctly identified in Setup. This error 
probably means your BIOS is corrupted, run the setup 
utility and set all settings to the default conditions. If you 
still get this error, contact your support representative.
*Operating system not found 
Operating system cannot be located on either drive A: or 
drive C: Enter the setup utility and see if both the fixed 
disk, and drive A: are properly identified and that the 
boot sequence is set correctly. Unless you have changed 
your installation greatly, the operating system should be 
on drive C:. If the setup utility is correctly set, your hard 
drive may be corrupted and your system may have to be 
re-installed from your back up media.
*Parity Check 1 nnnn 
Parity error found in the system bus. BIOS attempts
to locate the address and display it on the screen. If it 
cannot locate the address, it displays ????. This is a
potentially data destroying failure. Contact your
support representative.