Chapter 3  Web Operation 
IP-900 Series 
37 
After the completion of the settings, click the 
 button.  The message below appears. Click 
OK to apply the settings.  *Reboot is not required. 
 
 
 
Table 3-7  Data Port Setting Items 
 Item  Description 
Parameter 
Data port 
Specify whether to use data port 
communication. 
- Enable 
- Disable (Default) 
Operation mode 
Specify the operation mode of data 
port communication. 
- TCP server mode (bidirectional)
   (Default) 
- TCP server mode (receiving only) 
- TCP client mode (bidirectional) 
IP version 
Set the IP address version 
- IPv4 (Default) 
- IPv6 
Destination IP 
address 
Specify the IP address of the data 
communication destination when 
"TCP client mode (bidirectional)" is 
set for [Test mode]. 
- IPv4 (Default) 
- IPv6 
Operation 
settings 
 
Specify the IP address of the data 
communication destination when 
"TCP client mode (bidirectional)" is 
set for [Test mode]. 
Other than 0.0.0.0 
(Default: 0.0.0.0) 
Server mode 
Specify the port number of the own 
device when "TCP server mode 
(bidirectional)" is set for [Test mode].
1024 to 64000 
(Default: 6000) 
Specify the port number of the own 
device when "TCP client mode 
(bidirectional)" is set for [Test mode].
0 or 1024 to 64000 
(Default: 0) 
* If o is specified, a port number from 
1024 to 4096 is automatically selected. 
Port number 
settings 
Client mode 
Specify the port number of the 
destination device when "TCP client 
mode (bidirectional)" is set for [Test 
mode]. 
1024 to 64000 
(Default: 6000) 
RS-232C 
settings 
Timeout 
Specify in milliseconds the reception 
timeout time for RS-232C. 
20 to 200ms (Default: 20) 
* The duration to detect a time-out is 
defined as "the set value rounded down 
by a multiple of '20[ms]'" + "RS-232C 
polling interval of the device (20[ms])".
ex) 
When '60' is set, the duration will be 
'60' + '20' = 80 [ms] 
When '50' is set, the duration will be 
'40' + '20' = 60 [ms]