Справочник Пользователя для Ciprico Rimfire 3880

Скачать
Страница из 230
21020285 D
User’s Guide
 Chapter 4   Command Operation
Page 4 - 14 
Some Example Single Commands 
5.
The example board is jumpered at address EE00H. The three writes to 
the Address Buffer Port at address EE00H will be as follows:
1.) 843DH
2.) 0008H
3.) 22F4H
6.
Read the Hardware Status Port at address EE10H. Since the ENT bit of 
the Status Port toggles between 0 and 1 with each Single Command 
Channel Attention issue, the value returned could be 0202H or 0203H 
depending on the previous value. We’ll assume this is the first 
command after a reset; the initial value of the ENT bit is 0. The adapter 
is ready if the Status Port reads 0202H.
7.
To execute the command, write a 0 to the Channel Attention Port.
8.
Poll for command completion by reading the Flags Byte of the Status 
Block and comparing it to zero. When the value is non-zero, the 
command is complete. The value of the Flags byte in the Status Block 
will indicate if the command completed with an error. In this example, 
the command was successful; a value of 80H is returned as shown 
below. A returned value of C0H would indicate an error had occurred.
Figure 15 Single Command Structure in memory