Turning the System Off (All Models)
In order to shut off the system and prevent the Aprilaire
Control Panel from turning on your equipment, you need to
set ALL of your thermostats to the OFF mode. 
Depending on
your thermostats, this is done manually with a slide switch on
your thermostat’s sub-base or with a digital push button. Consult
the Owner’s Manual for your particular thermostat.
If leaving the home for a long period of time, set the Zone 1
thermostat to the Heat mode and adjust the set point to a
temperature that will prevent freezing in all areas of the home.
It is not recommended to turn off all thermostats for extended
periods in climates where freezing temperatures may occur.
System Pressure Relief 
With a Zoned Comfort Control System, some form of
pressure relief must be designed into the system to assure
proper operation and reduce the possibility of noise due to
airflow. The method of pressure relief that has been designed
into your system could include use of a bypass damper or the
Aprilaire method of controlled pressure relief. With the
controlled pressure relief method, a predetermined amount of
air is allowed to pass through a closed damper. The amount
of air that is passed by each damper (the bypass) is not
enough to cause a noticeable temperature change in a non-
calling zone, but is enough to relieve the higher system
pressures.
So, if you feel small amounts of air entering into a non-
calling zone, what you are feeling is the bypass air.
Remember, this bypass is normal and provides pressure
relief for the system without causing a noticeable change
in temperature within that zone.
Maintenance
Once your Aprilaire Zoned Comfort Control System is
properly installed, there is no maintenance required.