Self Contained Wireless Alarm System v1.0
2
1.1 Installation:
1
2
3.
If required, separate the front and back covers by remov-
ing the cover screw then inserting a small slotted screw 
driver between the front and back covers and gently twist 
the screwdriver to separate. 
Route Telephone line wiring, I/O Wiring, and AC power 
through a single or double ganged junction box and 
through cutout in the back cover see Fig. 2 Mounting & 
Wiring details. If Programming with DLS, See “4.1 Local 
Programming with PC-Link” on page 10. If using Template 
programming or Advanced Keypad programming continue 
to the next step.
Secure the back cover to the junction box with the screws 
provided (2 screws for single gang box or 4 screws for a 
double ganged box). For drywall (surface mount) secure 
to wall using 4 #6 3/4” wood screws and drywall plugs. 
See figure 2, Mounting & Wiring Details for hole locations.
Figure 1, Opening Cover
If mounting unit on a double ganged box with the wall 
tamper feature, secure the back plate to the right side of 
the ganged box using the center mounting holes. This will 
provide the tamper switch with unobstructed access to the 
wall surface
4. Connect wiring to the terminals indicated. See Section 1.2 
Wiring for details.
Figure 2, Mounting & Wiring Details
Do NOT apply power until wiring is completed.
5. Connect battery cable connector to the PC Board.
Ensure connector key is oriented correctly.
6.
7.
8.
9.
10.
11.
12.
Position the cover onto the back plate. Ensure tamper 
switch is positioned for effective operation.
Insert cover in the lower slot at a 35° to 55° angle then 
snap cover in place. An audible click will be heard.
Apply power to System.
Enroll devices. Enter [ ][8][Installer Code][898].               
See Section 2, Wireless Device Enrollment.
If performing Template programming, enter [ ][8][Installer 
Code][899]. See Section 3, Template Programming
Enter Advanced Programming if required.                          
See Section 5, Advanced Programming.
Test System by violating zones and verifying successful 
transmission to the central station. 
See DLS Programming on page 10 for reprogramming an 
existing Installation.
AC Power must be present for the Alarm system to answer
Incoming calls from DLS
After the initial installation 24 Hrs. is required to fully charge 
the standby battery.
Insert Screwdriver in slots indicated
Gently pry open cover with screwdriver
until cover separates
Remove cover screw
Tamper Switch
Third Hand
Cover screw hole
Strain Relief
Battery
Tamper Switch
Mounting Holes (6) - Ganged box
Mounting Holes (4) - Drywall
Wiring Access
Telephone Line
12 V
DC
PGM/Zones
AC Power
Red    Grn    Gra     Brn
AC      AC
Aux
1  I/O 2
+
-
Ring
Tip     R-1
T-1
WWW.DIYALARMFORUM.COM