2.8 
Alarm Reset Switch 
The gate operator is equipped with a built-in reset switch that will silence the entrapment alarm and 
return the operator to normal operation after a hard shutdown occurs.  An auxiliary reset button may 
be added provided that the following condition is met. 
•  The alarm-reset button must be located in the line of sight of the gate. 
Connect the normally open alarm-reset switch to auxiliary terminals 13 and 15. 
 
13
14
15
Common
Alarm
Alarm Reset
AUXILIARY ALARM RESET
PUSH BUTTON
OPERATOR
RESET
NORMAL
OPERATION
 
2.9 Auxiliary Stop Switch 
This circuit creates an auxiliary stop input that will stop a moving gate when activated, or will prevent 
the gate operator from starting if the switch is activated. Note that this stop input is normally open 
and that a switch closure will activate the stop function.  Because this is a normally open 
circuit, the stop switch is not intended and should never be used as a safety interlock device. 
•  This circuit cannot be used if a DoorKing 3 button control station is connected to the operator. 
•  Place a jumper wire from terminal 7 to terminal 8. 
•  Connect the stop switch to terminals 7 and 13. 
 
 
N.O
.
N.
C.
CO
M
Common
Open Only
Close Only
7
13
OPERATOR
STOPPED
NORMAL
OPERATION
AUXILIARY STOP USING
MAGNETIC SWITCH
N.
C.
N.O
.
CO
M
8
 
28