Справочник Пользователя для Denso BHT-7000

Скачать
Страница из 175
100
S
O
H
E
T
X
C
R
C
S
T
X
E
T
X
C
R
C
S
T
X
E
T
X
C
R
C
D
L
E
D
L
E
D
L
E
D
L
E
D
L
E
D
L
E
I
D
I
D
I
D
(2 bytes)
(5 bytes)
[ 3 ] Basic Format of Transmission Messages
Basically, the BHT-7000 transmits data as units of a file.  First, it transmits a heading
text which includes the attribute information of a file (e.g., file name and the number of
data texts) to be transmitted.  Following the heading text, it transmits the data text in
the file.  A heading text and data text comprise a text.
In  actual  text  transmission,  the  text  is  divided  into  several  blocks,  then  a  header,
terminator, serial number, receiver station's ID, and CRC-16 (Cyclic Redundancy Check)
are  added  to  each  block.    This  procedure  forms  a  transmission  block.    A  set  of
transmission blocks makes up one transmission message.
Shown  below  is  an  example  of  a  transmission  message  formed  with  the  BHT-Ir
protocol.
In the above figure, DLE SOH, DLE STX and DLE ETX are text control characters as
described in [ 2 ] Control Characters, (2).  An ID denotes the ID number of the receiver
station, expressed by two bytes.  A serial number is expressed by a five-digit decimal
number, starting from 00001 to 32767, and identifies data texts.  For the CRC-16, refer
to Appendix B, B.2, "BHT-Ir protocol, " [ 3 ].
You can use the control characters for expressing IDs, serial numbers, or text data.
Data text 1
Data text 2
Data text n
Heading
text
Transmission
Message
Data text 1
Transmission
block
Transmission
block
Text
Heading text
Serial
number
Data text 2
Serial
number
Transmission
block