Справочник Пользователя для Denso BHT-7000

Скачать
Страница из 175
119
Chapter 5.  Handling the CU-7000  (Option)
5.4.3 Interfacing with the Host Computer
This section describes how to start communication with the host computer in System
Mode.  The same may apply when you use a user program.
(1)
Power on the host computer.
(2)
Plug the AC adapter of the CU-7000 into the wall socket.
(3)
Make sure that the BHT-7000 is powered off, then set it on the CU-7000.
(4)
Power on the BHT-7000 and run System Mode.  Set the communications environ-
ments (communications protocol, interface port, communications parameters,
and protocol options).
Regarding  the  communications  protocol:    When  using  Ir-Transfer  Utility  C/Ir-
Transfer Utility E on the host computer, select the BHT-Ir protocol; when using
Transfer Utility, select the BHT-protocol.
Regarding the interface port:  Select the optical interface port.
(5)
On the host computer, initiate a communications program (e.g., Ir-Transfer Utility
C/Ir-Transfer Utility E/Transfer Utility, or equivalent).
(6)
To transfer data stored in the BHT-7000 to the host computer, select "3: UPLOAD"
on the SYSTEM MENU in System Mode.  To transfer data from the host computer
to the BHT-7000, select "2: DOWNLOAD."  (For details, refer to Chapter 2, Section
2.5.)
The BHT-7000 and the host computer will start communications with each other
via the CU-7000.  The DATA LED will come on upon start of communications.
After completion of communications, the LED will go off.
(7)
Unplug the AC adapter of the CU-7000 from the wall socket.