■ Phase 3 with timeout at the receiving station
If the receiving station receives no subsequent text or normal sequence of DLE EOT
and IDs within 30 seconds after sending a sequence of DLE ACK and IDs, it sends a
sequence of DLE EOT and IDs and aborts the transmission abnormally.
and IDs within 30 seconds after sending a sequence of DLE ACK and IDs, it sends a
sequence of DLE EOT and IDs and aborts the transmission abnormally.
Sending
station
station
Data text #n
DLE ACK and IDs
DLE EOT and IDs
Receiving
station
station
30 seconds
[ 2 ] Aborting Data Transmission
Pressing the C key aborts data transmission.
If the C key is pressed during downloading, the BHT transmits a sequence of DLE EOT
and IDs and aborts the file transmission.
and IDs and aborts the file transmission.
If it is pressed during uploading, the BHT transmits the current transmission block
followed by a sequence of DLE EOT and IDs and then aborts the file transmission.
followed by a sequence of DLE EOT and IDs and then aborts the file transmission.
Abnormal
termination
termination