Motor Phasing, Power-On Mode: Ixx73, Ixx74, Ixx80, Ixx81, Ixx91 
The Geo Brick  Drive supports a variety  of phasing procedures for commutated (brushless)  motors. This 
section discusses the following phasing methods: 
 
 
 
WARNING 
An  unreliable  phasing  search  method  can  lead  to  a  runaway 
condition. Test the phasing search method carefully to make sure 
it  works  properly  under  all  conceivable  conditions,  and  various 
locations of the travel. Make sure the Ixx11 fatal following  error 
limit is active and as tight as possible so the  motor will be  killed 
quickly in the event of a serious phasing search error. 
 
 
Note 
In  general,  it  is  NOT  recommended  to  execute  any  phasing  search 
moves  on  power  up  using  Turbo  PMAC’s  automatic  setting  (Ixx80). 
Motor phasing should be inserted in a power-on plc before which it is 