Справочник Пользователя для Delta Tau GEO BRICK LV
Geo Brick LV User Manual
PinOuts and Software Setup
23
PINOUTS AND SOFTWARE SETUP
WARNING
Installation of electrical control equipment is subject to many
regulations including national, state, local, and industry guidelines
and rules. General recommendations can be stated but it is
important that the installation be carried out in accordance with
all regulations pertaining to the installation.
regulations including national, state, local, and industry guidelines
and rules. General recommendations can be stated but it is
important that the installation be carried out in accordance with
all regulations pertaining to the installation.
TB1: 24VDC Logic Input
This 3-pin Phoenix Terminal Block is used to bring in the 24-Volt DC supply to power up the logic
portion of the Geo Brick LV. This power can remain on regardless of the main DC bus power, allowing
the signal electronics to be active while the main motor power control may be passive.
portion of the Geo Brick LV. This power can remain on regardless of the main DC bus power, allowing
the signal electronics to be active while the main motor power control may be passive.
The 24Volts power supply must be capable of providing 2~4Amps per Geo Brick LV. If multiple drives
are sharing the same 24-Volt power supply, it is highly recommended to wire each drive back to the
power supply terminals separately.
are sharing the same 24-Volt power supply, it is highly recommended to wire each drive back to the
power supply terminals separately.
This connection can be made using a 22 AWG wire directly from a protected power supply.
Pin #
Symbol
Function
Description
Notes
1
+24VDC
Input
Logic power input +
+16~32VDC
2
CHGND
Ground
Chassis ground
Connect to Protection Earth
3
+24VDC RET
Common
Logic power return -
Connect to Power Supply Return
Phoenix Contact mating connector part# 1735879
Delta Tau mating connector part# 016-090A03-08P
Delta Tau mating connector part# 016-090A03-08P
1
2
3
24 VDC
Power Supply
+24VDC
COM