21
Testing/Resetting the Ground 
Fault Interrupter (GFI)
the optional outdoor grill cart is equipped with a GfI to 
minimize the risk of injury due to an electric shock in the 
event of a short circuit. If your outdoor grill is connected 
to a GfI outlet that is not part of a Dacor grill cart, the 
following instructions still apply.
A GfI detects the possibility of an electric shock condi-
tion and disconnects power to the electrical receptacles 
next to the buttons. When the GfI disconnects (or trips), 
the reSet button on the outlet pops out slightly. the GfI 
should be tested periodically to make sure it is working 
properly.
to test a gFi:
Disconnect all power plugs from all of the receptacles 
1. 
on the GfI electrical outlet.
Push in on the teSt button and release.
2. 
the reSet button should trip immediately. 
3. 
Push in on the reSet button after it trips to turn 
4. 
power back on.
if the reSet button does not pop out during testing: 
Keep all plugs disconnected from the electrical outlet. 
1. 
Call a licensed electrician to have the outlet repaired. 
2. 
Do not use the outlet until repairs are made.
if the gFi trips when the teSt button is not being 
pushed:
Push in on the reSet button.
• 
if the gFi trips immediately when reset or when an 
appliance is turned on: 
Disconnect all plugs from the outlet and push the 
1. 
reSet button. If the GfI trips immediately, leave all 
appliances disconnected and call a licensed electrician 
to repair the electrical outlet. Do not use the outlet 
until it is repaired.
If the GfI does not trip with all the appliances dis-
2. 
connected, plug in the appliance/rotisserie plugs and 
turn them on one at a time. If the GfI trips when an 
appliance/device is plugged in and turned on, call for 
service. See page 24 for service information.
Standard “U” Burner Removal 
and Replacement
 warning
to avoid an electrical shock and fire hazard, be sure 
• 
to disconnect the outdoor grill power cord from the 
electrical outlet and close the gas shut-off valve when 
cleaning or servicing the burners.
Do not disassemble the appliance unless it is cool.
• 
the “U” burners can be removed for cleaning and inspec-
tion. models OB36 and OB52 are equipped with three,  
models OBS36 and OBS52 are equipped with two.
to remove:
Disconnect the outdoor grill power cord from the elec-
1. 
trical outlet.
Close the gas shut-off valve.
2. 
Open the canopy and remove the grates and flame 
3. 
spreaders from the grill compartment.
remove the burner cap nuts. they are located on the 
4. 
inside back panel just above the end of each burner.
Lift the burner up at the back and slide towards the 
5. 
back of the compartment to remove.
to reinstall:
Slide the mounting pins and gas supply tube on each 
1. 
burner into the holes on the back of the control panel 
inside the grill compartment. Slide the hole on each 
burner bracket over the studs at the back of the com-
partment.
Attach the burner brackets to the studs using the 
2. 
existing cap nuts.
Re-install the flame spreaders and grates.
3. 
reconnect the power cord. turn on the gas supply and 
4. 
test the burners for proper operation.
On units equipped with a LP tank, close the gas shut-