Equipment Installation Manual, 
GEN-X Electronic Flight Bag 
 
 
1069-2510-01 D.doc
 
 
1069-2510-01 
Rev D 
Page 10 of 27
 
SPECIFICATIONS: 
Physical: 
The GEN-X RPU attaches to its mount through two .25” guide pins and a two lock turn wing nuts.  The 
mount is attached to the airframe via four mounting holes.  See the paragraph titled Outline Drawing for 
further details. 
 
RPU 
Height.................................................2.655” (Includes mounting flange) 
Width..................................................8.561” (Includes mounting flange) 
Depth..................................................12.810” (Includes mounting flange) 
Weight................................................7.8 lb. (Includes mounting flange) 
DU 8” 
Height.................................................9.90”  
Width..................................................6.90”  
Depth..................................................1.705”  
       Weight………………………………3.4 lb. 
 
DU 10” 
Height.................................................11.60”  
Width..................................................8.13”  
Depth..................................................1.705”  
       Weight………………………………4.6 lb. 
 
 DU 12” 
Height.................................................13.00”  
Width..................................................9.20”  
Depth..................................................1.76”  
       Weight………………………………5.6 lb. 
   
Electrical: 
       Emergency Buss                                        (Monitored only) 
Input Voltage .....................................28 VDC Nominal  (10Vdc – 32Vdc operational) 
Input Current......................................0.001 Amp at 28 VDC 
Essential Buss 
Input Voltage .....................................28 VDC Nominal  (10Vdc – 32Vdc operational) 
Input Current......................................3.1 Amp at 28 VDC