12. Troubleshooting 
 
In the rare occasion that  you experience difficulties using this product, please read the following suggestions from 
the table below before contacting our support team. 
 
Symptom 
Description 
Solution 
Data 
doesn’t 
seem 
to 
be 
received  by  the  product,  but 
seems to be sent by it (e.g. data 
only travelling in one direction) 
This  is  normally  the  result  of  the 
product  being  configured  as  requiring 
RTS/CTS  handshaking,  but  being 
plugged into a  device  which does not 
support it. 
Firmware prior to 3.0 requires that pins 
7  and  8  (RTS  and  CTS)  of  the  9  pin 
connector are connected to each other 
(looped  back).  Firmware  from  3.0 
onwards 
can 
switch 
off 
this 
requirement 
– 
refer 
to 
Error! 
Reference  source  not  found.  Error! 
Reference  source  not  found.
  for 
details on how to do this. 
Interaction 
with 
the 
menu 
appears  slow  and  unresponsive, 
but data does show eventually. 
This  is  normal  operation  when  the 
product is in Client mode. The product 
is  using  most  of  its  processor  cycles 
to  try  and  find  and  connect  to  a 
remote device. 
Reconfigure  the  product  to  Server 
mode  whilst  attempting  to  configure 
other options 
Cannot interact with the menu 
There  are  a  number  of  scenarios 
where this might happen… 
1. A Bluetooth connection is made 
2. The  Product  has  failed  to  initialise 
correctly  (perhaps  if  the  power 
adapter  has  been  attached  whilst 
switched on). 
3. Incorrect 
communication 
parameters selection. 
4. Incorrect Wiring configuration 
  1.  No  interaction  with  the  menu  is 
possible  when  a  Bluetooth  connection 
is  present.  Break  the  connection  to 
restore access to the menu. 
  2. Switch the power off then on again.  
  3.  Change  the  communication  settings 
in  your  terminal  application  to  match 
those  of  the  devices  settings.  If  you 
have  forgotten  or  lost  these  settings, 
then  the  device  can  be  restored  to  its 
factory  settings  by  performing  a  long 
reset.    Check  your  devices  wiring  and 
handshake configuration requirements 
   
Firmware upgrade (DFU Wizard) 
fails 
1. Product not connected 
2. Product not configured for upgrade 
  1. Connect your converter to a suitable 
port  on  your  PC  and  connect  the 
power. 
  2. Follow instructions in above sections 
for preparing for upgrade