Справочник Пользователя для Brainboxes RS232

Скачать
Страница из 41
 
 
 
 
 
Manual for BL-521 5_3.doc 
© Copyright Brainboxes Limited 2004 
Page 9 of 41
 
3.5. Current Settings 
 
 
The  Current  Settings  section  is  broken  down  into  two  sections; 
Local  Device  Settings  and  Partner  Device  Settings.    Each  field 
will be discussed further below. 
 
When  the  Current  Settings  has  been  selected,  an  additional 
section  appears  in  the  left-hand  section  called  Default  Settings.  
Both  sections  can  be  expanded  at  the  same  time  to  enable  the 
user  to  view  the  current  settings  and  the  default  settings  at  the 
same time. 
 
As  each  section  is  opened,  the  previously  opened  section  will 
close  to  prevent  information  moving  off  the  bottom  of  the  screen 
and thus requiring the user to scroll down. 
 
Whenever  a  setting  is  changed,  the  field  changes  colour  to 
indicate that a change has been made but not applied.  
 
 
Baud Rate 
Click the drop down arrow at the far right of this field to display a list of popular baud rates. Due to some technical 
limitations,  it  is  not  possible  for  the  product  to  achieve  all  of  these  baud  rates  exactly,  although  most  of  them  are 
available to within 1%. Normal RS232 operation is not affected by such small differences in data rates unless very 
long streams of continuous data are being used. The Actual baud rate achieved is displayed next to your selection. 
 
This  option  is  only  applied  when  the  “Apply”  icon  is  clicked.    Along  with  updating  the  device,  the  application  will 
immediately change its own communications parameters to match those new settings so it can continue to interact 
with the device. Multiple changes to communications settings are ALL applied when the “apply” icon is selected. 
 
NOTE: It is possible for the converters to be configured to baud rates that are not supported by a PC’s COM port. If 
your  application  requires  such  a  “non-standard”  baud  rate,  you  may  no  longer  be  able  to  communicate  to  the 
converter from your PC. If you “apply” the setting inadvertently, you can restore the original settings of the converter 
by performing a reset as documented below. 
 
The converter’s normal factory set baud rate is 115200 baud. 
 
Parity 
Click the drop down arrow at the far right of this field to display the available options for Parity. 
This  option  is  only  applied  when  the  “Apply”  icon  is  clicked.  Along  with  updating  the  device,  the  application  will 
immediately change its own communications parameters to match those new settings so it can continue to interact 
with the device. Multiple changes to communications settings are ALL applied when the “apply” icon is selected. 
 
Stop Bits 
Click the drop down arrow at the far right of this field to display the available options for Stop Bits. 
This  option  is  only  applied  when  the  “Apply”  icon  is  clicked.  Along  with  updating  the  device  the  application  will 
immediately change its own communications parameters to match those new settings so it can continue to interact 
with the device. Multiple changes to communications settings are ALL applied when the “apply” icon is selected. 
 
Data bits 
Unfortunately  this  setting  cannot  be  changed.  BL-521  only  supports  the  8  data  bit  format.  Thus  there  is  not  a 
configuration menu option for this setting.