Mounting
1.
Bring the plug-in module into position with the horizontal terminal lettering facing the front side of the control 
panel. Slide the plug-in module carefully into position along the guide rails (refer to Figure 2Page 5, Item 1)
2.
Ensure that the connections seat into the slot properly (refer to Figure 2Page 5, Item 2).
3.
Press down softly until the snap-fit hook locks into place (refer to Figure 2Page 5, Item 3).
Figure 2
Installing the FPE-1000-CITY City Tie Plug-in Module
To remove a plug-in module, press the snap-fit hook carefully from left to right and pull the board toward the panel 
front.
Wiring
No special wire is required for addressable loops. The wire can be untwisted, unshielded, solid or stranded as long 
as it meets the National Electric Code 760-51 requirements for power-limited fire protective signaling cables.
Observe a maximum circuit resistance of 65
Ω.
Note: Use the appropiate DIP switch setting at the module to obtain the desired operation mode (refer to Figure 1
Page 4).
Reverse Polarity Mode
The FPE-1000-CITY connects the FPA-1000 Analog Addressable Fire Panel to either a single set or a pair of dual 
leased telephone company (telco) lines in NFPA 72 Remote Station applications. The FPE-1000-CITY relays system 
alarm status information from the control panel to a monitoring station.
In normal conditions, the FPE-1000-CITY sends a steady current to a monitoring station. In an alarm condition, it 
reverses the polarity of the output current. The FPE-1000-CITY signals a trouble condition by interrupting the output 
voltage and current.
The default setting is fire alarm for circuit 1 and supervisory for circuit 2. 
FPE-1000-CITY 
DIP Switches
S1 = SUP
S2 = ALM
1
2
3
1
2
3
Reverse Polarity Mode
ON
ON
ON
ON
ON
ON
Local Energy
OFF
OFF
OFF
OFF
OFF
OFF
Note: You may use different operation modes for the circuits. The DIP switch settings 1 to 3 for each switch (S1 
and S2) must be set to the same position.
NOTICE! 
Intended for connection to a polarity reversal circuit of a remote station receiving unit having 
compatible ratings.
Terminal
Default setting
Figure 3
Reverse Polarity Mode
ALM - | +
Fire Alarm
SUP - | +
Supervisory
Legend
M
Monitoring Station
@  
_
.  :  ,
?
A  a
Gas Alarm
Silenced
Power
Trouble
Fire
Supervisory
DRILL
RESET
SILENCE
ACK
2
1
1
3
ALM -+
-
+
SUP
M