Справочник Пользователя для Bosch Appliances Home Security System ICP-CC404

Скачать
Страница из 98
ICP-CC404 | Installation Guide | 11.0   Dialer Information 
 
 
48 Bosch 
Security 
Systems, 
Inc. | 12/08 | F01U089401-02
 
When using Domestic Dialing Format, the number of 
identification beeps is determined by the value 
programmed in Location 039 (Receiver 1) and 
Location 079 (Receiver 2). This value allows the 
identification of up to 15 different control panels that 
call the same telephone number. 
Example 
To program the Subscriber ID Number as 4729, 
program: 
0  0  4  7  2  9 
11.6 Dialing 
Format 
Program the Dialing Format in 
Location 080.  
The default value for the Dialing Format is 
1. 
The Dialing Format determines the method for 
dialing telephone numbers. The options are: 
1 – Australian DTMF (5 digits/sec) 
2 – Australian decadic 
3 – Alternate DTMF and Australian decadic 
4 – International DTMF (touch tone) 
5 – Reversed decadic (10 minus 1) 
6 – Alternate DTMF and reversed decadic 
Options 3 and 6 alternate the dialing sequence 
between DTMF and decadic if the call to the base 
station receiver is unsuccessful. Use caution when 
selecting the dialing method. 
Select the Australian method only if the control panel 
is connected to the Australian Telecommunications 
Network. Select the International DTMF dialing 
option only in countries that allow both the caller and 
the receiver to terminate a phone call. Using the 
incorrect format can disable the control panel’s 
patented Telephone Anti-Jamming feature. 
 
 
The alternating sequence is: DTMF – 
decadic – DTMF – decadic – DTMF – 
decadic. 
 
11.7 Telco 
Arming 
Sequence 
Program the Telco Arming Sequence in 
Locations 113 
to 142.  
The default value for the Telco Arming Sequence is  
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 
These locations allow you to activate call diversion 
automatically on your telephone when you arm the 
system in AWAY Mode. Refer to Table 39
 
 
 
 
Table 39: 
Telco Arm or Disarm Dialing Digits 
 
Digit 
Required 
Number to 
Program 
Digit 
Required 
Number to 
Program 
terminator 
1 1  9  9 
10 
3 3  * 
11 
12 
5 5  4 
sec 
pause 
 
13 
break 
14 
7 7   
 
 
When the Telco Arming Sequence is activated after 
arming the system in AWAY Mode, the control panel 
redirects all calls to your mobile phone, pocket pager, 
or answering service.  
Contact your telecommunications provider for more 
information on Call Forward operations. 
To turn call forward (immediate) on, enter: 
[* 2 1][forwarding telephone number][#] 
Example 
To immediately forward all incoming calls to the 
telephone number 96721055 after arming the system 
in AWAY Mode, program: 
[11  2 1 9 6 7 2 1  10  5 5  12  0 0 0 0 0 0 0 0 0 0 0 0 
0 0 0 0 0 0] 
To turn call forward (no answer) on, enter: 
[* 6 1][forwarding telephone number][#] 
Example 
To forward all incoming calls, when there is no 
answer, to the telephone number 96721055 after 
arming the system in AWAY Mode, program: 
[11  6 1 9 6 7 2 1  10  5 5  12  0 0 0 0 0 0 0 0 0 0 0 0 
0 0 0 0 0 0] 
11.8 Telco 
Disarming Sequence 
Program the Telco Disarming Sequence in 
Locations 143 to 158.  
The default value for the Telco Disarming Sequence 
is 
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 
This parameter allows you to deactivate call diversion 
automatically on your telephone when you disarm the 
system from AWAY Mode. Refer to Table 39
To turn call forward (immediate) off, enter: 
[# 2 1 #] 
Example 
To disable call forward (immediate) after disarming 
the system from AWAY Mode, program: 
[12  2  1  12  0 0 0 0 0 0 0 0 0 0 0 0]