Листовка для Atlantis Land A03-HP2001 HostPower 2001 A03-HP2001
Модели
A03-HP2001
PRODUCT: Host Power Sinewave Line Interactive UPS 2000VA
Model Number: A03-HP2001
EAN CODE: 80269740062353
Model Number: A03-HP2001
EAN CODE: 80269740062353
ATLANTIS LAND S.p.A. Viale De Gasperi, 122 - 20017 Mazzo di Rho (MI)
Tel. 02 9390.6085 - Fax 02 9390.6161 - www.atlantis-land.com - info@atlantis-land.com
PRODUCT: Host Power Sinewave Line Interactive UPS 3000VA
Model Number: A03-HP3001
EAN CODE: 80269740062360
Model Number: A03-HP3001
EAN CODE: 80269740062360
PRODUCT: Host Power Sinewave Line Interactive UPS 1000VA
Model Number: A03-HP1001
EAN CODE: 8026974006239
Model Number: A03-HP1001
EAN CODE: 8026974006239
PRODUCT: Host Power Sinewave Line Interactive UPS 1500VA
Model Number: A03-HP1501
EAN CODE: 80269740062346
Model Number: A03-HP1501
EAN CODE: 80269740062346
MODEL
Power Rating
Power Rating
Power Rating
INPUT
OUTPUT
TRANSFER Line/Battery
DISPLAY & DIAGNOSTICS
Communication Port
Environmental Condition
SAFETY APPROVAL
DIMENSION (W*H*D cm)
Weight (N.W/ G.W) Kg
Environmental Condition
SAFETY APPROVAL
DIMENSION (W*H*D cm)
Weight (N.W/ G.W) Kg
LCD Display
LED Display
Beeping Alarm
Advanced Mode
VOLTAGE
Single Phase; 220/230/240V selectable by DIP Switch ( 25% )
±
50Hz
5%
±
Inverter mode: 3%
±
Pure Sine-Wave with THD 3% at linear load
Inverter mode: 50Hz or 60Hz
0.1Hz
±
Nearly Zero Transfer (<6ms typical)
With LCD & LED Display
USB DB9 port with TRUE RS232 serial signal plus dry contact signals
/
0-40°C; 0-95% Non Condensing Humidity
CE/UL
Normal, AC Input High, AC Input Low, On Battery,
Battery Low, Battery Bad, Overload, Fault, Phase error,
Ground Fault
Utility Voltage, Ouput Voltage, Output Hz, Load%,
UPS Temperature, Battery Voltage, Runtime Timer
Battery Low, Battery Bad, Overload, Fault, Phase error,
Ground Fault
Utility Voltage, Ouput Voltage, Output Hz, Load%,
UPS Temperature, Battery Voltage, Runtime Timer
Green=Normal, Amber=Warning, Red=Critical
LCD shows detalis in respect to the lighting indication of LED
LCD shows detalis in respect to the lighting indication of LED
Overload, Fault, High Temperature, Battery On, Battery Low,
Battery Bad, Over/Under Voltage, Frequency Error
Battery Bad, Over/Under Voltage, Frequency Error
Self-diagnostic; Direct Time-based readout of battery
remained runtime
remained runtime
Status:
Data:
9 min
Sealed Maintenance Free Lead Acid VRLA Type
Switch to Battery Output when the Utility over regulation range
>110% Buzzer continuosly alarms & shuts down after 10 minutes
Two stages, no battery drain after cut-off
Full time suppression
Meet with IEEE 587 cat. A&B Standard
RJ11 / RJ45
960 Joules instantaneous response
Better than 45dB @1Mhz for Normal/Common mode
EN50991-1
4*IEC(Battery Power Supply) + 1*Schuko
RS232(DB9) and USB
Hz
VOLTAGE(INV)
WAVEFORM(INV)
Hz(INV)
Half-load runtime
Capacity
Quantity
Recharge Time
Type
Overload(AC INV)
/
Low Battery
EMI/RFI
Surge Protection
Modem/Network
Energy Rating
Attenuation
Noise Filtering
Output
Computer
BATTERY
PROTECTION
A03-HP1001 A03-HP1501 A03-HP2001 A03-HP3001
1000 VA
600 W
12V 7Ah
/
12 9Ah
/
12 7Ah
/
12 9Ah
/
2
2
4
4
1500 VA
900 W
2000 VA
1200 W
3000 VA
1800 W
Over/Under Volt.
17*24*37
15
16
23
26
CONNECTIONS
17*24*47
2-4 Hours to 90%
VOLTAGE(AC)
Increase 15% (Input:-9% to -25%); Decrease 15% (Input:+9% to +25%)
Input Fuse
Electronic Circuit
&
Electronic Circuit
/
Short Circuit(AC INV)
/
Company Certified ISO 9001:2000