WARNING
WARNING
- 2 -
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1.
Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer at the address or telephone number 
listed in the warranty.
2.
Before servicing or cleaning unit, switch power off 
at service panel and lock service disconnecting 
means to prevent power from being switched on 
accidentally. When the service disconnecting 
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3.
Installation work and electrical wiring must be done 
by qualified personnel in accordance with all 
applicable codes and standards, including fire-rated
construction codes and standards.
4.
Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of 
fuel burning equipment to prevent backdrafting. 
Follow the heating equipment manufacturer’s 
guidelines and safety standards such as those 
published by the National Fire Protection 
Association (NFPA), and the American Society for 
Heating, Refrigeration and Air Conditioning 
Engineers (ASHRAE), and the local code authorities.
5.
When cutting or drilling into wall or ceiling, do not 
damage electrical wiring and other hidden utilities.
6.
Ducted fans must always be vented to the 
outdoors.
7.
Do not use this unit with any other solid-state 
speed control device.
8.
To reduce the risk of fire, use only steel ductwork.
9.
This unit must be grounded and protected by a 
GFCI.
10.
Suitable for use in damp locations only when 
installed in a GFCI PROTECTED branch-circuit.
11.
This unit is not designed for use with a charcoal 
grill.
TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
a)
Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low 
or medium settings.
b)
Always turn hood ON when cooking at high heat or 
when flambeing food (i.e.: Crêpes Suzettes, 
Cherries Jubilee, Peppercorn Beef Flambé).
c)
Clean ventilating fans frequently. Grease should 
not be allowed to accumulate on fan or filter.
d)
Use proper pan size. Always use cookware 
appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING*:
1.
SMOTHER FLAMES with a close-fitting lid,
cookie sheet or metal tray, then turn off the
burner. BE CAREFUL TO PREVENT BURNS. IF 
THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2.
NEVER PICK UP A FLAMING PAN – You may
be burned.
3.
DO NOT USE WATER, including wet dishcloths or 
towels – This could cause a violent steam explosion.
4.
Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you
know how to operate it.
B. The fire is small and contained in the area 
where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1.
For general ventilating use only. Do not use to 
exhaust hazardous or explosive materials and 
vapors.
2.
To avoid motor bearing damage and noisy and/or 
unbalanced impellers, keep drywall spray, 
construction dust, etc. off power unit.
3.
Your hood motor has a thermal overload which will 
automatically shut off the motor if it becomes 
overheated. If the motor stops, discontinue cooking.
The motor will restart when it cools down. If the 
motor continues to shut off and restart, have the 
hood serviced.
4.
The minimum hood distance above cooktop must 
not be less than 30”. A maximum of 36” above 
cooktop is highly recommended for best capture of 
cooking impurities.
5.
Two installers are recommended because of the 
large size and weight of this hood.
6.
To reduce the risk of fire and to properly exhaust 
air, be sure to duct air outside – Do not exhaust air 
into spaces within walls or ceiling or into attics, 
crawlspaces or garage. 
7.
This product is equipped with a thermostat which 
may start blower automatically. To reduce the risk 
of injury and to prevent power from being switched 
on accidentally, switch power off at service panel 
and lock or tag service panel.
8.
Because of the high exhausting capacity of this hood,
if used indoors, you should make sure enough air 
is entering the house to replace exhausted air by 
opening a window close to or in the kitchen.
9.
To reduce the risk of fire and electrical shock, the 
Best model 
WPD28I must be installed only with 
internal blower model P12D (sold separately). 
Other blowers cannot be substituted. 
10.
Use with approved cord-connection kit only.
11.
Please read specification label on product for 