Справочник Пользователя для BENDIX TCH-008-012

Скачать
Страница из 5
The discharge line unloader valve which is generally located just ahead of the first
reservoir (the “wet tank”), must be removed.  An air dryer and D-2 governor can then be
installed per our instruction and they will perform the compressor unloading function
formerly provided by the discharge line unloader valve.
Attached are partial schematics detailing the piping of the air dryer and governor
combination along with the metric fittings required to complete the installation.  Installing
the air dryer and governor on a single mounting plate allows the use of U.S. fittings and
tubing for the control and sensing lines for the governor and air dryer.  Only two Metric
fittings (if any) are required to install the air dryer in the compressor discharge line.  The
fittings shown on the attached schematics would allow Metric air lines to be connected to
devices with U.S. pipe threads.  On some overseas vehicles U.S. tubing sizes are used
but the fittings have Metric pipe threads.  Mack Midliners (MS-20) are examples of this.
In this case the fittings needed to install the air dryer and governor combination can be
standard U.S. fittings since the discharge line is 5/8” O.D. tubing and the pipe threads in
the AIR DRYER are U.S.
Metric fittings are not currently available from T.B.S. however several of the large fittings
manufacturers have complete catalogs and listings along with conversion fittings.