Справочник Пользователя для Behringer 02222FX

Скачать
Страница из 17
11
XENYX 1622FX/1832FX/2222FX/2442FX
via the high-precision MAIN MIX fader.
+
If  you  connect  a  compressor  or  a  noise  gate  post
2-track  output,  the  main  mix  fader  will  probably  not
be  able  to  create  a  satisfactory  fade-out  effect.
2.3.9 Lamp socket (2442FX only)
Use this BNC socket to connect a gooseneck lamp (12 V DC,
max. 0.5 A).
2.3.10 Level meter and monitoring
Fig. 2.16: Control room and phones sections of the 2442FX
CD/TAPE
The CD/TAPE switch routes the signal from the CD/TAPE INPUT
jacks to the level meter, the CONTROL ROOM OUT outputs and
the PHONES jack—this is a simple way to check recorded signals
via monitor speakers or headphones.
SUB 1-2 or SUB
The SUB 1-2 switch routes subgroup 1-2 to the level meter,
CONTROL ROOM OUT and phones.
SUB 3-4
The SUB 3-4 switch performs a similar function for subgroup
3-4 (2442FX only).
MAIN  MIX
The MAIN MIX switch sends the main mix to the CONTROL
ROOM OUT and the PHONES output as well as to the level meter.
PHONES/CTRL ROOM
Use this control to adjust the control room output level and the
headphones volume.
CD/TAPE TO MAIN
When the CD/TAPE TO MAIN switch is depressed, the 2-track
input is routed to the main mix and thus serves as an additional
input for tape machines. You can also connect MIDI instruments or
other signals here that do not require any further processing. At
the same time, this switch disables the main mix to tape output link.
POWER
The blue POWER LED indicates that the device is switched on.
+48 V
The red “+48 V” LED lights up when phantom power is switched
on.  Phantom  power  is  required  to  operate  condenser
microphones.
+
While  phantom  power  is  switched  on,  do  not
connect  or  disconnect  microphones  on  the  mixer
(or  the  stagebox/wallbox).  Connect  any  micro-
phones  before  switching  on  phantom  power.
Additionally,  monitor/PA  speakers  should  be  muted
before you activate the phantom power supply. After
switching  on,  wait  approx.  one  minute  before
adjusting  the  input  gain  so  that  the  system  has  time
to  stabilize.
LEVEL METER
The high-precision level meters always give you an accurate
display of signal level.
LEVEL SETTING:
When recording to digital recorders, the recorder’s meter should
not go into overload. This is because, unlike analog recordings,
it takes only slightly excessive levels to create unpleasant digital
distortion.
When  recording  to  analog,  the  VU  meters  of  the  recording
machine should reach approx. +3 dB with low-frequency signals
(e.g. kick drum). Due to their inertia, VU meters tend to display
too low a signal level at frequencies above 1 kHz. You should
only  drive  instruments  such  as  a  Hi-Hat  as  far  as  -10 dB.
Snare drums should be driven to approx. 0 dB.
+
The peak meters of your XENYX display level almost
independent  of  frequency.  A  recording  level  of  0  dB
is  recommended  for  all  types  of  signal.
MODE
The  MODE  switch  determines  whether  the  channels’  SOLO
switch operates as PFL (Pre Fader Listen) or as solo (Solo In
Place).
PFL (LEVEL SET)
To activate the PFL function, press the MODE switch. The PFL
function should, as a rule, be used for level setting (TRIM). The
signal is sourced pre-fader and assigned to the mono PFL bus. In
“PFL” mode, only the left side of the peak meter is in operation. A
PFL’d channel should be driven to the 0 dB mark of the VU meter.
SOLO (NORMAL)
When the MODE switch is not depressed, the stereo solo bus
is  active.  Solo  is  actually  short  for  “Solo  In  Place”.  This  is  the
customary  method  for  listening  to  an  individual  signal  or  to  a
group of signals. As soon as a solo switch is pressed, all channels
not solo selected are muted in th e monitor path (control room
and  phones).  A  channel’s  position  in  the  stereo  image  is
maintained. The solo bus carries the output signals of the channel
pan controls, the aux sends and the stereo line inputs. On the
2442FX all aux returns, and on the 1832FX only aux return 2 can
be routed to the solo bus. The solo bus is, as a rule, taken post-
fader.
+
The  PAN  control  in  the  channel  strip  offers  a
constant  power  characteristic.  This  means  that  the
signal  is  always  at  a  constant  level,  irrespective  of
position  in  the  stereo  panorama.  If  the  PAN  control
is  moved  fully  left  or  right,  the  level  in  that  channel
increases  by  4  dB.  This  ensures  that,  when  set  at
the  center  of  the  stereo  image,  the  audio  signal
does  not  appear  louder.  For  this  reason,  with  the
solo function activated (Solo in Place), audio signals
from channels with PAN controls that have not been
moved  fully  left  or  right  are  displayed  at  a  lower
volume  than  in  the  PFL  function.
As  a  rule,  solo  signals  are  monitored  via  the  control  room
outputs  and  headphones  jack  and  are  displayed  by  the  level
meters.  If  a  solo  switch  is  pressed,  the  signals  from  the  tape
input, the subgroups and the main mix are cut from these outputs
and the level meter.
MAIN SOLO
The MAIN SOLO LED lights up as soon as a channel or aux
send solo switch is pressed. The MODE switch must be set to
“Solo”.
PFL (LEVEL SET)
The PFL (LEVEL SET) LED indicates that the peak meter is set
to PFL mode.
Fig.  2.17:  PHONES  jack
2. CONTROL ELEMENTS AND CONNECTORS