5-4 Gap Sensor Manual-Calibration 
 
Manual-calibration of media detection can be used when the printer cannot detect a media 
gap (or black mark) even after auto-calibration has been executed. 
 
Users can calibrate sensor parameters in detail by using the utility program provided by 
the manufacturer.   
 
The utility can be obtained from the enclosed CD or downloaded from the Internet via the 
BIXOLON website    www.bixolon.com 
 
 
Please make sure the printer is connected and execute the utility program. 
Press the Calibration Setting Manager button after setting the interface type. 
 
 
 
 
 
 
1) Select proper values for "No. of detect" and "Detect margin" and press the Execute 
Manual Calibration button to make the printer begin media sensor calibration. 
 
2) Typically-used setting values are pre-saved in the Setting buttons (1~8). 
 
3) If the printer malfunctions while executing calibration, please turn off the printer and turn 
it on again. 
 
4) The sensor parameters can be set back to factory default settings by pressing the 
Cancel Calibration button.