Справочник Пользователя для Bil-Jax Wheelchair XLB-4232 DC

Скачать
Страница из 116
 
3 — OPERATION 
 
3-9 
3-5  BATTERY  RECHARGE  (DC  MODEL  ONLY) 
The DC boom lift batteries should be recharged after each 8-hour work shift or more 
often if needed. When the boom lift is not in use, the batteries should be recharged at least 
once per week. 
The normal charge time is 10 to 12 hours. If the battery charge is extremely low, a full 
recharge may take up to 24 hours.  
Recharge the DC boom lift batteries as follows: 
WARNING
 
Recharge the batteries in a well ventilated area only. Do not charge batteries near 
fire, flame, or other ignition sources. Batteries being charged may emit highly 
explosive hydrogen gas. Failure to properly ventilate the charge gases may result 
in serious injury or death. 
1.  Move the boom lift to a well ventilated area with direct access to a grounded  
120 VAC electrical outlet. Make sure the recharge area is not near fire, flame or 
other ignition sources.   
2.  Turn the BATTERY ON/OFF switch to the OFF position. 
3.  Plug a short, heavy-duty power cord into the battery charger receptacle on the 
front of the battery compartment. The recommended power cord should be an  
12 AWG multi-strand, grounded cord no longer than 20 feet (6 meters). 
NOTE: 
Using an underrated or long power cord will reduce the output of the 
battery charger, resulting in longer charge time. 
BATTERY
CHARGER
RECEPTACLE
BATTERY
CHARGER
 
Figure 3-6.   Battery Charger and Receptacle 
4.  Plug the power cord into a grounded 120 VAC receptacle. Verify that the red 
ON-CHARGING indicator LED lights up on the battery charger.