Справочник Пользователя для Behringer high-precision digital 24-bit/96 kHz EQ/RTA mastering processor DEQ2496

Скачать
Страница из 23
13
ULTRACURVE PRO DEQ2496
3. MENU STRUCTURE AND EDITING
SHOW MESSAGE BOX
Here,  you  can  determine  whether  the  unit  displays  dialog
windows  or  not.
RTA/MIC INPUT
Controls the input sensitivity of the RTA/MIC input. You can
choose between LINE LEVEL, MIC LEVEL and MIC LEVEL +15 V
(phantom  power).
RTA/MIC LINE LEVEL
When  the  RTA/MIC  input  is  set  to  LINE,  this  parameter
determines the maximum input level (for 0 dBFS (full-scale) from
-14 to +22 dBu).
RTA/MIC MIC LEVEL
When the RTA/MIC input is set to MIC, this parameter determines
the  sensitivity  depending  on  the  microphone  connected  (input
sensitivity: -42 to -6 dBV/Pa).
MIDI SETUP (page 2)
Fig. 3.19: UTILITY menu (page 2)
The DEQ2496 can both transmit and receive MIDI data and
thus works perfectly with other MIDI equipment.
MIDI
When  this  parameter  is  ON,  you  can  display  all  subsequent
MIDI configuration categories. When set to OFF, the DEQ2496
does not respond to any MIDI data.
MIDI CHANNEL
Here  you  can  select  the  MIDI  channel  (1-16)  on  which  the
ULTRACURVE PRO transmits and receives MIDI data.
CONTROL CHANGE
The exchange of CONTROL CHANGE data refers to the GEQ
module only (CONTROL CHANGE 1 - 31: left channel / CONTROL
CHANGE 33 - 63: right channel).
PROGRAM CHANGE
PROGRAM CHANGE commands (both send and receive) are
used  to  recall  presets  #1  to  64  as  well  as  the  default  setting
(preset #0: INITIAL DATA).
SYSTEM EXCLUSIVE
Your  DEQ2496  can  both  transmit  and  receive  sys-ex  data
(system  exclusive).
The  transmission/reception  of  MIDI  data  can  be  enabled  or
disabled specifically (ON/OFF). To be able to receive software
updates, RECEIVE SYSTEM EXCLUSIVE must be ON.
DUMP EDIT (A key)
This function allows you to transfer active settings via MIDI to
another ULTRACURVE PRO or a computer equipped with a MIDI
interface.
DUMP ALL (B key)
The  complete  memory  contents  (all  presets)  of  the
ULTRACURVE  PRO  can  be  transferred  via  MIDI  to  another
ULTRACURVE PRO or a computer equipped with a MIDI interface.
+
Caution:  the  reception  of  the  complete  memory
contents  from  another  unit  will  overwrite  all
existing  settings!  All  saved  presets  will  be
retained.
+
More  information  on  MIDI  can  be  found  in  chapter
5.1 “MIDI connections” and 7.1 “MIDI implementation”.
3.6 I/O menu
On the first three pages of this menu you can determine the
input/output  configuration,  while  the  fourth  page  allows  you  to
adjust the output signal delay function, for example to make up
for run-time differences, which occur when several P.A. speaker
stacks set up at a distance from each other are used.
Fig. 3.20: I/O menu (page 1)
On the first page you can select the DEQ2496’s input source
with the large data wheel. You can choose between the analog
MAIN INPUT, the digital inputs (DIGITAL XLR or DIGITAL OPT) and
the built-in PINK NOISE generator. Use the NOISE GAIN parameter
to  adjust  the  volume  level  of  the  noise  generator  (lower  data
wheel). The setting range is from -60 to 0 dB. The upper data
wheel  controls  the  sample  rate  (CLOCK)  used  by  the  device.
When the digital input has been selected, the sample rate cannot
be  changed,  because  the  DEQ2496  tracks  the  sample  rate
contained in the input signal. When the PINK NOISE generator is
on, the modules DEQ and DYN (not LIMITER) are switched off.
Fig. 3.21: I/O menu (page 2)
On the second menu page you can determine the signal source
for the AUX output and the digital outputs. Selectable options are
the unprocessed input signal (MAIN IN or DIG. IN), the processed
signal,  post-graphic/parametric  EQ  (BEHIND  GEQ/PEQ),  the
processed signal post-EQ and post-dynamics module (DYN), or
the  processed  signal  post-all  modules,  i.e.  post-stereo  imager
(BEHIND WIDTH).
Use the A key to select the consumer format (S/PDIF) or the
professional  digital  format  (AES/EBU).  The  upper  data  wheel
controls  the  resolution,  DITHER  (OFF,  24-bit,  20-bit  and
16-bit). The NOISE SHAPER function to be activated with the B
key reduces the dither-induced noise by moving it to a frequency
range where it is less audible.
+
If  the  connected  sample  rate  does  not  correspond
to  the  rate  adjusted  on  the  DEQ2496,  this  field
shows  the  message  UNLOCKED,  which  mutes  all
outputs  of  the  DEQ2496.
  
Fig. 3.22: I/O menu (page 3)
On the third page you can determine the input signal for the
real-time analyzer. Selectable options are MAIN IN (or DIG. IN),
MAIN OUT, AUX OUT/DIG. OUT (XLR and optical) and RTA/MIC
input.  When  you  select  the  RTA  microphone  input,  the  A  key
switches the input sensitivity from MIC to LINE, and vice versa,
while the B key enables or disables the phantom power supply
required  for  condenser  microphones  (MIC  +15  V),  if  the  input
sensitivity has been set to MIC.