DS72 HOST MODULE OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
15
by <cr>.  The DS72 module presents the current status of Port ID Echo and
asks if you want to change:
Port ID Echo is....................Disabled
Change It? (Y/N):
Type “Y” followed by <cr> to toggle Connect Port ID Echo or “N” for no
followed
  
by <cr>.   If you answer yes, the DS72 module responds:
Port ID Echo is...................Device Name
Disable Port ID Echo..............1
Use Module, Port Number...........2
Use Device Name...................3
Exit..............................X,CR
Enter Request :
If you are enabling Port ID Echo, choose #2 to echo the module and port
number, followed by <cr>.  Choose #3 to echo the device name, followed by
<cr>.  The DS72 module stores the selected Connect Port ID Echo in non-
volatile memory and returns to the configuration menu.
NOTE:  If you choose #3, “Use Device Name,” the programmed Port Device Name for the selected
DS74 is used.
LOGIN SETUP            
This  configures  how  the  DS72  responds  upon  login.    You  can
Enable/Disable the Header and Menu and/or Enable/Disable/Program
Password and Auto Connect Port.
From the configuration menu, select #8, “Login Setup,” followed by <cr>.
The following menu appears:
Header..........................1
Password........................2
Menu............................3
Auto Connect....................4
Exit............................X,CR
Enter Request :
Header 
If enabled, the following header appears with the main menu upon initiation
of power or after a modem connection to the host module has been
established. If disabled, the header does not appear with the main menu.
Default Header is enabled.
Data Switch Series – F.1.00
Bay Technical Associates
Unit ID:  BAYTECH DS72
Port Select Code:   $BT
Attention Character:   ;
From the selection menu, select #1, “Header,” followed by <cr>.  The DS72
displays the current header status and asks if you want to enable: