DS72 HOST MODULE OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
22
Allow approximately 10 seconds for the unit to reset.
ASCII                                    To reset the DS-Series Unit using the ASCII character string method,
Character
                    send the following command:
String
$BTRESET<cr>
DIAGNOSTICS                   To detect hardware, cabling, or configuration problems upon initialization
of power, the DS72 executes a diagnostic sequence.  To help determine
the cause of the problem, the DS72 has a CX LED located on the front
panel of the unit.  Upon initialization of power, refer to the following table
for interpretation.
INDICATION
INTERPRETATION
Not lit
Normal unconnected operation
Brief flash followed by a solid illumination
Established connection on network port or serial port
Flashes 1 time per cycle
Hardware or NIC problem
Flashes 2 times per cycle
Configuration error
Flashes 3 times per cycle
Cable or hub connection fault
Flashes 4 times per cycle
Duplicate IP address
Remains lit without a brief flash prior to
illumination
Memory error
NOTE:  Diagnostic indications override a connection indication.