DS72 HOST MODULE OWNER’S MANUAL
DS72 QUICK START
4
Copyright(C) Bay Technical Associates 1998
DS-72 Data Switch Series - Telnet Host Module
Revision F.1.00
Module 1
Status..........................1
Serial Port Configuration.......2
Port Device Name................3
Port Select Code................4
Attention Character.............5
Disconnect Timeguard............6
Connect Port ID Echo............7
Login Setup.....................8
Network Port Configuration......9
Unit ID.........................10
Configure Another Module........11
Exit............................X,CR
Type “9”, followed by <cr> to access the Network Port Configuration. The following menu is displayed:
Network Configuration
IP Address:  0.0.0.0
Subnet Mask: 0.0.0.0
Gateway:     0.0.0.0
Ethernet Address: 00.C0.48.06.1A.81
Connection Inactivity Timeout (mins): 0
Carriage Return Translation: Disabled
Break Length (msecs): 350
IP Address........................1
Subnet Mask.......................2
Gateway...........................3
Activity Timeout..................4
Carriage Return Translation.......5
Break Length......................6
Exit..............................X,CR
Enter Request :
Selections 1 and 2 will allow you to input the address in a dotted decimal format. For example, typing
“1”, followed by <cr> will display:
Enter IP address in dotted decimal form :
Enter the address in the following format: nnn.nnn.nnn.nnn where n is any number. If you are unsure
of this address, contact your network administrator. The subnet mask and gateway are programmed in a
similar fashion. When programming is complete, type “X” followed by <cr>. The system must be reset
for these settings to be applicable.
If this is not an initial set-up and password has been enabled, you are prompted to login.  After logging
in successfully, access the main menu by sending the attention character five times (;;;;;).