Инструкции По Установке для White Rodgers 36C03-300 Gas Valve

Скачать
Страница из 24
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY 
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE 
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
The 
36C03 and 36C10 series valves are designed 
to meet requirements for use on standing con-
tinuous pilot systems. 
36C03 combination models 
include a pressure regulator, 
100% shut-off auto-
matic pilot, and main operator. 
36C10 models do 
not have a pressure regulator. 
36C Inst
Voltage
# of 
Stages
Open 
Characteristics
Standing
Pilot
Intermittent Pilot 
Proven Pilot
HSI
DSI
36C03/36C10
24V
1
Fast
Yes
No
No
No
36C03U
750mV
1
Fast
Yes
No
No
No
36C03A
120V
1
Fast
Yes
No
No
No
PRESSURE REGULATOR ADJUSTMENT RANGE
EXCLUDING 
36C10 NON-REGULATED
Gas Type
Single Stage
Natural Gas
2.5–5.0
LP Gas
7.5–12.0
 
 
SPECIFICATIONS
 
 
DESCRIPTION
INSTALLATION INSTRUCTIONS
36C03, 36C03A, 36C03U & 36C10
Standing/Continuous Pilot Combination Gas Valve
OFF
PIL
OT
ON
ECO
Terminals
OFF
PIL
OT
ON
Pilot Gas Outlet: 
 
Located at outlet end of the valve
Type of Gas:  Suitable for all domestic heating  
 
      gases
Ambient Temperature: -
40º to 175ºF
Pressure Rating: 
14" W.C. (1/2 PSI) Max
Voltage/Current: 36C03U – 750mV
                                36C03/36C10 – 24V/0.23A
                                36C03A – 120V/0.035A 
CONTENTS
Description  ........................................................................... 
1
Specifications  ....................................................................... 
1
Precautions ........................................................................... 
2
Installation ............................................................................ 
3
 
System Wiring
Adjustment  .......................................................................... 
5
 
Pressure Regulator Adjustment
Lighting Instructions ............................................................
 6
Contents French ........................................................................9
Contents Spanish.....................................................................17
PIPE SIZES/CAPACITIES
Pipe Size
(inches)
Capacity (BTU/hr) at
1" pressure drop across valve
Range of Regulation
Excluding 
36C10 Non-Regulated
Nat. Gas
(
1000 BTU/cu. ft., 64 
Sp. Gr.)
LP Gas
(
2500 BTU/cu. ft.,
 
1.53 Sp. Gr.)
AGA Std. Nat. Gas
0.64 Sp. Gr.
(
1,000 BTU/cu. ft.)
LP Gas
1.53 Sp. Gr.
(
2,500 BTU/cu. ft.)
1/2" x 3/8"
100,000
162,000
15,000 - 100,000
15,000 - 162,000
1/2" x 1/2"
230,000
372,600
30,000 - 290,000
30,000 - 469,000
1/2" x 3/4"
230,000
372,600
30,000 - 290,000
30,000 - 469,000
3/4" x 3/4"
280,000
453,600
50,000 - 400,000
50,000 - 648,000
Parts and Accessories:
Conversion Kit
• F
92-0659 Nat. to LP Gas (7.5" to 12.0" W.C.)
• F
92-0737 Nat. to LP Gas (Non-regulated)
• F6
9-0727 1/4" brass compression fitting for pilot 
line connection
Thermocouple (
24V & 120V types): 
  Use W-R Type H
06
Pilot Generator (
.750 volt types):
  Use W-R Type G
01A-32
www.white-rodgers.com
www.emersonclimate.com
PART NO. 
37-7349B
Replaces 
37-7349A
1429