Каталог для White Rodgers 3046-5 Mercury Flame Sensors

Скачать
Страница из 1
MERCURY FLAME SENSORS
Prevent Gas Flow to Main Burner if Pilot Flame is Not Burning or is
Insufficient to Properly Ignite Main Burner
FEATURES
• These sensors combine a rugged Snap-Action switch and powerful mercury
  actuated thermal element.
• May be used with natural, manufactured or mixed gases and with LP gases where
  means are provided for obtaining automatic pilot gas shut-off.
• Switch may be conveniently mounted in any position.
• Cover is easily removed, making switch terminals readily accessible.
• No button to depress – Sensors are recycling type which require relighting or
  possible restoration of proper gas pressure to return to operation.
SPECIFICATIONS
Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . .   Contacts close approximately 60 seconds
   
  after pilot is ignited; open approximately
 
 40 seconds after flame is extinguished
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .   U.L. recognized and C.S.A. approved   
Dimension. . . . . . . . . . . . . . . . . . . . . . . . .  
2
3
/
4
H x 2
1
/
16
 W x 1
7
/
8
D
 
Model 
Element 
Electrical Rating
 
Number 
Length 
120 VAC 
240 VAC 
30 VAC
 
3046-5 
48” 
125 VA 
125 VA 
90 VA
PLUG-IN TYPE MERCURY FLAME SENSORS
Designed for use with White-Rodgers Diaphragm, “Cushioned Power” 
or “Silent Knight” Gas Valves having Plug-In Receptacle
FEATURES
• Plug-in feature requires no additional electrical connections or mounting devices.
• Sensor combines a rugged Snap-Action SPDT switch and powerful mercury
  actuated thermal element.
• May be used with natural, manufactured or mixed gases and with LP gases where
  means are provided for obtaining automatic pilot gas shut-off.
• No button to depress – Sensors are recycling type which require relighting or
  possible restoration of proper gas pressure to return to operation.
• The SPDT switch can energize ignitor circuit to relight pilot (as with roof top units).
SPECIFICATIONS
Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . .   Contacts close approximately 60 seconds
   
  after pilot is ignited; open approximately
 
 40 seconds after flame is extinguished
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .   C.S.A. approved
 
Model 
Element 
Electrical Rating
  Number 
Length 
120 VAC 
240 VAC 
30 VAC 
Comments
 
30A46-5 
48” 
125 VA 
125 VA 
90 VA 
stud mount element
 
30A46-105 
12” 
125 VA 
125 VA 
90 VA 
sleeve over element,
 
 
 
 
 
 
no stud mount
30A46-5
3046-5
GAS BURNER
CONTROLS
HEA
TING
www.white-rodgers.com
61