Инструкции Пользователя для White Rodgers ACB1400

Скачать
Страница из 8
7
1
1
3
2
CONDUIT
FLOOR
DUCT
AIR CLEANER
MAINTENANCE
For maximum efficiency, your air filter should be in-
spected once a month and changed if dirt loading is
heavy. When changing is required, the following proce-
dure should be used:
!
CAUTION
The fiber filter used in this compartment for air
cleaning must be replaced every 90 days. Your
heating and cooling efficiency will decrease due
to insufficient air flow when filter becomes dirty.
1.
Remove door from air filter compartment by unscrew-
ing the knob.
2.
Remove 5
 filter and throw away.
3.
Replace 5
 filter by sliding it into the compartment.
(Note direction of air flow.)
4.
Replace door.
When ordering repair parts, always give the following
information as shown in this list.
1. The PART NUMBER
2. The PART DESCRIPTION
3. The MODEL NUMBER of  the Air Filter Compart-
ment
Always order by “PART NUMBER” . . .
Not by “ITEM NUMBER”
PARTS LIST FOR
AIR FILTER COMPARTMENT
REPAIR and UPGRADE PARTS
Vertical
Section
Wood Block
Tape All
Joints
Part Number
Item
No.
Description
1000
1400
1600
2000
1
Compartment  & Door
ACB1000
ACB1400
ACB1600
ACB2000
2
Filters 5”
FR1000
FR1400
FR1600
FR2000
3
Screw, Fastener
F870-0026 F870-0026 F870-0026 F870-0026
Figure 15
Figure 16
Description
1000
1400
1600
2000
Electronic Air Cleaner Retrofit Kit ACR1000
ACR1400
ACR1600
ACR2000
ELECTRONIC AIR CLEANER KIT
UPGRADE!