Proper Log Placement
Log placement is critical to proper burner performance. Logs must 
be correctly positioned onto the burner. The photos in this manual 
show the proper pinned position for logs on this set. Owners need 
to be shown proper log placement and instructed not to move the 
logs. 
Logs must fit firmly onto the burner when positioned as shown in 
the photos. Misformed logs or logs with sloppy pin holes must be 
replaced.
Proper Placement of rock wool and Decorative Lava rock
Rock wool can be added to burners for a glowing ember effect. 
It must be positioned only on the front portion of the burner. The 
photos in this manual  show the proper placement of rock wool.
Decorative lava rock or small wood pieces should never be placed 
on the burner. These items are only for placement on the floor of 
the fireplace or firebox.
Proper Primary Airflow into Burner
For  proper  burner  operation  and  flame  appearance,  the  flow  of 
primary air into the venturi tube, located on the rear of the burner, 
must not be reduced. This flow of air is reduced if dirt, lint or other 
obstructions build-up around or inside the venturi. Any obstruction 
in the venturi tube area must be removed. The flow of air into the 
venturi is also reduced if the gas orifice isn’t centered in the venturi 
inlet and/or is not aligned with the venturi. Any misalignment of the 
burner orifice may be corrected by bending the shutter cap holding 
the orifice to the inlet of the venturi tube.
ceiling fans, Portable fans or Logs Installed Near cold Air 
returns
Ceiling fans or oscillating floor type fans need to be monitored 
during the operation of vent-free logs. If the air blows directly 
into the flame causing it to impinge on the log set, or firebox, it 
should be turned off or redirected. Ceiling fans could be reversed 
to possibly eliminate flame impingement, and the floor fan could 
be redirected. Upon installation, be aware of any cold air returns 
or vents in the proximity of the log set. Any draft created around 
a vent-free log set can cause the flame to impinge on the log and 
create a sooting situation.
wArNINg: Do not allow fans to blow directly into the fireplace. 
Avoid any drafts that alter burner flame patterns.
wArNINg: Do not use a blower insert, heat exchanger insert or 
other accessory not approved for use with this heater.
candles
Avoid the use of scented or decorative candles while the log set is in 
operation. Candles produce a residue in the air that creates a soot like 
substance. Burning candles while the log set is operating magnifies 
the problem. It should be noted that candles, in general, produce 
soot. The amount of time burned and the quantity of candles burned 
will determine the amount of soot produced and deposited.
Make Owners Aware of Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit 
soot on the logs. If users see soot appear on a log, call for service. 
Do not continue to operate the log set.
Sunken fireplace
If installing this unit into a sunken fireplace, you must raise the 
floor to insure adequate airflow and guard against sooting. Raise 
fireplace floor using a non-combustible material, which is secure.
glass Doors
Make sure that glass doors are open during all operations of the 
logset. The opening of the glass door frame should be the dimension 
used for the minimum front opening of the firebox.
woodburning fireplaces
The interior of the firebox and the chimney should be cleaned and 
free of all creosote before installing a gas burning log set. Creosote 
will soften when heated and can drop on the logset causing odors 
and possibly sooting.
wArNINg: Before installing in a solid-fuel burning fireplace, the 
chimney flue and firebox must be cleaned of soot, creosote, ashes 
and loose paint by a qualified chimney cleaner.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip-
ment or accessories and repair and servicing of equipment shall 
be  performed  only  by  a  qualified  agency. The  term  "qualified 
agency"  means  any  individual,  firm,  corporation,  or  company 
that either in person or through a representative is engaged in and 
is responsible for (a) the installation, testing, or replacement of 
gas piping or (b) the connection, installation, testing, repair, or 
servicing of equipment; that is experienced in such work; that is 
familiar with all precautions required, and that has complied with 
all the requirements of the authority having jurisdiction.
The installation must conform with local codes or, in the absence 
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54.*
*Available from the American National Standards Institute, Inc. 11 West 42nd 
St., New York, N.Y. 10018.
State of Massachusetts: The installation must be made by a 
licensed plumber or gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural gas-fired supplemental 
room heaters shall provide to each purchaser a copy of 527 
CMR 30 upon sale of the unit.
IMPOrTANT INSTALLATION guIDeLINeS
geNerAL INfOrMATION