23340-4-0608
Page 8
15”
(381mm)
TOP EDGE OF FIREPLACE
12” (305mm)
10” (254mm)
MANTEL
COMBUSTIBLE TRIM AND MANTELS
ALLOWED IN SHADED AREA
4”
5”
6”
7”
8”
9”
11”
13 3/4”
3/4”
1 ½”
2 1/4”
3”
3 3/4”
4 ½”
6”
8”
3”
Mantel Chart (Figure 3)
Figure 3
Clearances (Figure 4)
Clearance from top of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
Figure 4
Figure 5
Note:**  Island  (C)  and  Room 
Divider (D) installation is possible 
as long as the horizontal portion 
of  the  vent  system  (H)  does  not 
exceed  20  feet  with  a  minimum 
vertical run of 8 feet. See details 
in Venting Section.
*When you install your Direct Vent 
Fireplace in (D) Room divider or 
(E) Flat on wall corner positions, 
a minimum of 6 inches clearance 
must  be  maintained  from  the 
perpendicular  wall  and  the  front 
edge of the appliance.
Figure 2
Combustible Material
No greeting cards, stockings or ornamentation of any type should 
be placed on or attached to the fireplace. The flow of heat can 
ignite combustibles.
CABINET
INSTALLATION
FLUSH WALL
INSTALLATION
ROOM DIVIDER
INSTALLATION
CORNER
INSTALLATION
ANGLED CORNER
INSTALLATION
ISLAND
INSTALLATION
Clearance to Combustibles
Back
0" (0 mm)
Side
0" (0 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
3" (76 mm)
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
NON-COMBUSTIBLE
FIRST 3 (SEE MAGNIFFIED
VIEW)
NAILING
FLANGES
GLASS FRONT
TOP FRAMING
LEDGE
FINISHED WALL
(COMBUSTIBLE)
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
2" x 4" HEADER
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOP OF
FIREPLACE
3"
CLEARANCES
LOCATING FIREPLACE