Справочник Пользователя для Siemens AC75

Скачать
Страница из 569
AC75 AT Command Set  
10.8 AT^SISW
s
AC75_ATC_V01.002
Page 283 of 569
10/30/06
Confidential / Released
 
10.8
AT^SISW Internet Service Write Data
Th
 command triggers a write operation (upload) and queries the amount of data already sent, but not
acknowledged at the TCP layer. The write operation may be run in binary mode, or in interactive text mode. 
Th
 write command may return the following errors: 
 if there is a problem on application, socket, PPP or GPRS/GSM level. The
 command and the "
" URC offer additional error information. 
 e.g. if the service has not network resources allocated. 
 e.g. if the service is not configured. 
Syntax
Unsolicited Result Code
^SISW: 
Data availability status of the Internet service configured with 
 has changed. The URC is issued when
the service is ready to accept new user data. 
The URC is disabled in polling mode. See 
Parameter Description
0...1500
Specifies the number of bytes to be sent wit
 or, if set to 0, requests the amount of data already sent
with 
 but not yet acknowledged: 
• Parameter 
 may be 1...1500 bytes to specify the amount of data to be sent with
• If parameter 
 equals 0, 
 does not expect any data, but a normal query is per-
fomed. This allows the application to explictly request, in particular at the end of an upload job, the amount of
unacknowledged data at the TCP layer indicated by 
• In interactive text mode, 
 must be set to any value greater than 0 (but not necessarily
the precise number of bytes). If set to 0 in interactive text mode, 
 would be interpreted
as query for unacknowledged data and, thus, prevent data transfer. 
Test Command
AT^SISW=?
Response(s)
OK 
Write Command
[, 
[, 
Response(s)
Number of data bytes as specified by 
OK 
ERROR 
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
±
+
+
+
+
+
+
-
-
+
<srvProfileId>
(num)
<reqWriteLength>
(num)