Справочник Пользователя для Mitsubishi Electronics Mitsubishi Digital Electronics Automobile Accessories Frequency Inverter
27
MITSUBISHI ELECTRIC
FR-F 740 EC/E1
611
Acceleration time at a restart
0–3600 s / 9999
5 s / 15 s
햳
867
AM output filter
0–5 s
0.01 s
869
Current output filter
0–5 s
0,02 s
872
Input phase failure protection selection
0 / 1
0
882
Regeneration avoidance operation selection
0 / 1
0
883
Regeneration avoidance operation level
300–800 V
760 V DC
884
Regeneration avoidance at deceleration detection sensitivity
0–5
0
885
Regeneration avoidance compensation frequency limit value
0–10 Hz / 9999
6 Hz
886
Regeneration avoidance voltage gain
0–200%
100%
888
Free parameter 1
햲
0–9999
9999
889
Free parameter 2
햲
0–9999
9999
891
Cumulative power monitor digit shifted times
햲
0–4 / 9999
9999
892
Load factor
햲
30–150%
100%
893
Energy saving monitor reference (motor capacity)
햲
0.1–55 kW / 0–3600 kW
햳
Motor capacity at 120% / 150% overload
capacity
894
Control selection during commercial power-supply operation
햲
0 / 1 / 2 / 3
0
895
Power saving rate reference value
햲
0 / 1 / 9999
9999
896
Power unit cost
햲
0–500 / 9999
9999
897
Power saving monitor average time
햲
0 / 1–1000 h / 9999
9999
898
Power saving cumulative monitor clear
햲
0 / 1 / 10 / 9999
9999
899
Operation time rate (estimated value)
햲
0–100% / 9999
9999
C0 (900)
CA terminal calibration
햲
Calibration range
—
C1 (901)
AM terminal calibration
햲
Calibration range
—
C2 (902)
Terminal 2 frequency setting bias frequency
0–400 Hz
0 Hz
C3 (902)
Terminal 2 frequency setting bias
0–300%
0%
125 (903)
Terminal 2 frequency setting gain frequency
0–400 Hz
0 Hz
C4 (903)
Terminal 2 frequency setting gain
0–300%
100%
C5 (904)
Terminal 4 frequency setting bias frequency
0–400 Hz
0 Hz
C6 (904)
Terminal 4 frequency setting bias
0–300%
20%
126 (905)
Terminal 4 frequency setting gain frequency
0–400 Hz
50 Hz
C7 (905)
Terminal 4 frequency setting gain
0–300%
100%
C8 (930)
Current output bias signal
0–100%
0%
C9 (930)
Current output bias current
0–100%
0%
C10 (931)
Current output gain signal
0–100%
100%
C11 (931)
Current output gain current
0–100%
100%
989
Parameter copy alarm release
10 / 100
햳
10 / 100
햳
990
PU buzzer control
햲
0 / 1
1
991
PU contrast adjustment
햲
0–63
58
PR.CL
Parameter clear
0 / 1
0
ALLC
All parameter clear
0 / 1
0
Er.CL
Alarm history clear
0 / 1
0
PCPY
Parameter copy
0 / 1 / 2 / 3
0
PARAMETER
Notes:
햲
These parameters can be changed during operation if parameter 77 is set to 0 (factory setting).
햳
The possible setting values depend on the capacity class of the inverter.
햴
A setting of 9 is possible on models 01800 and above.
햵
This setting is possible on models 01800 and above.
햶
Setting of 100 to 103, 114 to 117 are possible on models 01800 and above.
햷
Setting of 7 and 107 are possible on models 01800 and above.