3 
Enabling Auto Negotiation 
Configure Auto Negotiation on the McPC 100Mbps by adjusting a two-position 
switch, labeled AN, on the faceplate next to the fiber connectors.  Enable this feature 
by moving the switch to the up ON position.  Disable (default) by moving the switch 
to the down OFF position. 
LED Indicators 
The McPC 100Mbps features four diagnostic LEDs.  These LED functions include the 
following: 
 
FX RCV 
Blinks yellow when the McPC 100Mbps is receiving data 
TX LNK 
Glows green when a twisted pair link is established 
FA 
Glows green when FiberALert is enabled 
FX LNK 
Glows green when a fiber link is established 
 
 
 
LinkLoss and FiberAlert  
The McPC 100Mbps includes the troubleshooting features FiberAlert, TXLL, and FXLL 
that help locate silent failures on a network.  Before attempting to install the 
module(s), understand how these features work and react to specific network 
configurations.   
 
WARNING  
Installing modules without understanding the effects of LinkLoss and FiberAlert can cause 
functioning units to appear flawed or even nonfunctional. 
Link Integrity 
During normal operation, link integrity pulses are transmitted by all point-to-point 
Ethernet devices.  When an IMC Networks media converter receives valid link pulses, 
it knows that the device to which it is connected is up and sending pulses, and that 
the copper or fiber cable coming from that device is intact.  The appropriate “LNK” 
(link) LED is lit to indicate this.