Справочник Пользователя для HP Cell Phone Accessories E6380-90019

Скачать
Страница из 228
82
Chapter 4 
CDMA Measurements - Screens and Control Fields
Average Power Measurements
Average Power Measurements
CDMA Measurements
Average Power Measurements
Avg Pwr 
Avg Pwr
 displays the average power level of all signals at the RF 
IN/OUT port. The units (watts, volts, or dBm) can be changed by 
positioning the cursor in front of the units field and then pressing the 
desired units key. (See 
.) Refer to the 
HP 8935 CDMA Base Station Tests Applications Guide for more 
information about average power measurements.
Screens on which this measurement is displayed.  
• CDMA ANALYZER
• CDMA GENERATOR
ADC FS
ADC FS
 is displayed when average power is measured. ADC FS 
indicates how close the measured power level is to the maximum 
allowed input level at the RF IN/OUT port for a particular 
Pwr Gain
 
setting (on the CDMA ANALYZER screen). Changes to ADC FS can be 
made by altering the
 Pwr Gain
 field setting and by altering the signal 
level into the RF IN/OUT port. ADC FS should be between 
1.0 and 
−10
 
dB when the 
Pwr Gain
 field is set to 
Auto
, and can be manually set up 
to 
0.5 dB when set to 
Hold
. The measurement will be aborted if ADC 
FS goes above 
0.5 dB. Measurement accuracy may be degraded if ADC 
FS goes below 
10 dB.