Chapter 2  Setup
13
P2X0-0202-01EN    ETERNUSmgr User Guide -Introduction-
All Rights Reserved, Copyright © FUJITSU LIMITED 2007
2
Polling Interval
This parameter is used to control polling (periodically checking the status) of a target device.
Set the polling interval in units of seconds within the range of 1 ~ 65535. 
[Default value]
300
[Parameter]
POLLING_TIME (1-65535)
[Example]
POLLING_TIME=300
This specifies the Polling Interval (time between the start of one poll to the next).
Due to network or device load the actual polling time may exceed the set time. In such cases, the start of
the next polling time is delayed until the previous polling finishes:
When the actual polling finishes within the scheduled polling time:
When the actual polling exceeds the scheduled polling time:
Caution: 
Unless there is some special reason to change this parameter, it is recommended to keep the
default. For this reason the parameter is initially commented out.
Target Type
Sets the target device type. Two parameters are provided: TARGET_TYPE and TARGET_FLAG
These parameters cannot be omitted. ETERNUSmgr will not start if these parameter have not been set.
[Parameter]
TARGET_TYPE (up to 256 characters)
[Example]
Any character string can be used to describe the target device type.
When the type of target device is ETERNUS3000:
TARGET_TYPE=ETERNUS3000
150 sec
150 sec
150 sec
200 sec
300 sec
300 sec
300 sec
300 sec
Per schedule
Per schedule
Per schedule
Scheduled polling 
interval
Actual polling 
interval
Scheduled start OK
400 sec
150 sec
150 sec
450 sec
300 sec
300 sec
300 sec
300 sec
Schedule
recalculated
Scheduled polling 
interval
Actual polling 
interval
Per schedule
Schedule
recalculated
Scheduled 
start NG
Delayed start