 Troubleshooting
General/ Power Supply Verification  -   2 2
 
Power Supply Verification
 
To start up, the Power Mac G4 logic board requires a “trickle” 
power of +5V for AGP and PCI models, +28V for Gigabit Ethernet/
Digital Audio models, or +25V for QuickSilver models. If the 
system fails to start up, follow the procedure outlined below to 
determine whether the problem is related to the power supply.
 
Note:
 
 To verify the power supply, you need a volt meter.
 
Verification Procedure
 
Follow the procedures in the Take Apart chapter to access the 
power supply.
 
Important:
 
  For this verification procedure when connecting the 
volt meter leads to specific pins, ensure the power supply cable 
remains securely plugged into the power supply connector on the 
logic board.