Инструкция С Настройками для Burnham ES2 ES2

Скачать
Страница из 52
4
The IQ Boiler Control stores two boiler supply 
temperature setpoints in its memory; one setpoint 
is for the High Limit Setting and the second is for 
the Operating Setpoint. 
APPENDIX H – IQ CONTROL SySTEM
IQ Control System overview 
The “IQ Control System” consists of an IQ Boiler 
Control and an IQ Option Panel with optional “plug 
in” cards:  
•   Fully integrates both factory and field 
installed components, simplifying installation 
and troubleshooting.  
•  Efficiently operates the entire boiler system 
to save energy.
IQ Boiler Control:
The heart of Burnham’s IQ Control System is the 
IQ Boiler Control.  The IQ Boiler Control replaces 
the traditional separate ignition control, primary 
boiler aquastat, as well as the fan and circulator 
relays. 
IQ option Panel:
The IQ Option Panel works together with the IQ 
Boiler Control to provide an easy and convenient 
means to “plug-in” additional functionality to a 
boiler system.
The IQ Option Panel is a standard component 
provided along with the IQ Boiler Control.  The 
IQ Option Panel functions as a “motherboard” 
to accept up to three (3) IQ Option Cards and 
provides the necessary mechanical connections 
(with no screws required), along with the power 
and interconnection wiring into the IQ Boiler 
System.  Only wiring from field-installed sensors 
is required.  The IQ Option Panel includes a 
dedicated digital readout that provides option card 
status information, diagnostics and setup functions 
when necessary.
•  Ensures adequate heat and supply of 
domestic hot water. 
•  UL / CSA Listed or Recognized and tested 
as part of a complete system.
 
Communicate with other EnviraCom
™ 
enabled components to provide a complete 
system solution to maximize comfort and 
energy efficiency.
When the optional Outdoor Air Reset Card is 
installed in the IQ Option Panel, the Operating 
Setpoint temperature is automatically adjusted 
according to the outdoor temperature.  For 
example, as the outdoor temperature increases 
the Operating Setpoint temperature is reduced 
from the High Limit Setting to save energy 
while improving home comfort.  By better 
matching boiler heat supply to actual home 
heat demand, room air temperatures are more 
closely maintained.  In addition, when there is 
a domestic hot water (DWH) heat request, the 
Operating Setpoint temperature is automatically 
adjusted to a DHW Setpoint to satisfy the DWH 
heating requirements.  When the Outdoor 
Air Reset Card is not installed the Operating 
Setpoint equals High Limit Setting.