Справочник Пользователя для Raritan Computer Paragon II 255-30-6000-00
Chapter 4: Operation - Administrator Functions
111
Product family
Number of
outlets
outlets
Rack space
Corresponding device
option in the OSUI
option in the OSUI
PCR8/8A series
8
1U rack mount
PCR8
PCS12/12A series
12
0U vertical mount
PCS12
PCS20/20A series
20
0U vertical mount
PCS20
PCR20/20A series*
20
2U rack mount
PCS20
* The corresponding device type for model PCR20/20A series in the
Paragon OSUI is the “PCS20” option.
Paragon OSUI is the “PCS20” option.
A special Raritan Power CIM (P2CIM‐PWR) is available for use with this
kind of power strip. Attach this CIM to the RJ45 port on the Power Strip,
and then connect the power strip into an AC source. Connect the CIM to
one of the channel ports on a Paragon switch.
kind of power strip. Attach this CIM to the RJ45 port on the Power Strip,
and then connect the power strip into an AC source. Connect the CIM to
one of the channel ports on a Paragon switch.
Configuring and Naming the Power Strip
Activate the Paragon II OSUI by logging into the system or pressing the
hot key (default: Scroll Lock) twice quickly. The new Power Strip should
appear in the appropriate channel port with the name PCR8, PCS12, or
PCS20, depending on the model type. The Power Strip will be treated
exactly like a tiered device.
hot key (default: Scroll Lock) twice quickly. The new Power Strip should
appear in the appropriate channel port with the name PCR8, PCS12, or
PCS20, depending on the model type. The Power Strip will be treated
exactly like a tiered device.
1. Press F5 to activate the Administration Menu.
2. Select option 3, “Channel Configuration,” and press Enter.
3. Select the Power Stripʹs channel port, and edit the name of the Power
Strip. The appropriate model type should already be selected in the
Device column.
Device column.
4. Press S to save the changes.
5. If you want to configure the individual power outlets on the Power
Strip, press G to enter the “Outlet Configuration” Menu.
6. When finishing the configuration, press S to save the changes.
Associating a Device with a Power Outlet
Since Paragon II cannot detect which type of device is connected to which
power outlet, associations of devices with individual power outlets must
be done manually.
power outlet, associations of devices with individual power outlets must
be done manually.
1. Press F5 to activate the “Administration Menu.”
2. Select option 3, “Channel Configuration,” and press Enter.