Справочник Пользователя для Pelco PelcoNet NET300 Multimedia Transmission Via Network C2908M-B

Скачать
Страница из 96
84
C2908M-B (4/05)
CONNECTING PELCONET TO A CM6700 ASCII PORT
Figure 50.  Using PelcoNet with CM6700 to Provide Remote Control
1
3
5
7
9
2
4
6
8
10
11
12
14
13
15
16
1
2
VIDEO INPUTS
ALARM S
(1-9 )
ALARM S
(10-18)
COM 1 (1-6)
CO M 2 (7-12)
CONTROL
OUTPUTS
REMOTE KEYBOARD(S)
LOCAL
KEYBOARD
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12
0 1 2 3
F
2
F
3
N
O
N
C
C
O
M
T T
R R
+
+
ETHERNET CONNECTION
TO NETWORK (LAN/WAN)
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
RS-422/485
ON
OF F
KEY
RS-232
SW5 DIP SWITCH SETTINGS
SET DIP SWITCH (SW5) ON
CM6700-MXB TO RS-232 MODE
CM6700 MATRIX COM 2
PORT SETTINGS:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
2-RX
3-TX
5-GND
PELCONET
TRANSPARENT
DATA PORT
CM6700-MXB
COM 2 (7-12)
2 RXD......................
3 TXD.....................
5 GND.....................
7  TXD
12 RXD
9 GND
PELCONET CM6700 ASCII SETUP SPECTRA COAXITRON   PROTOCOL
TRANSMITTER
Video In
SPECTRA
VIDEO OUTPUTS
Video In
Video In
Video In
RS232/422/485
TRANSPARENT DATA PORT
USING INTERNET EXPLORER; SET
TRANSPARENT DATA SETTINGS
ON BOTH PELCONET RECEIVER
AND TRANSMITTER:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1